User Tools

Site Tools


tuning_the_s800_xdt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
tuning_the_s800_xdt [2015/10/29 13:38]
pereira [Timing setup]
tuning_the_s800_xdt [2017/04/08 13:42]
pereira [Dispersion Matching Mode]
Line 68: Line 68:
  
   * Set trigger to “s800 trigger”    * Set trigger to “s800 trigger” 
-      * Ensure that the **[[s800 daq tools#trigger GUI|trigger GUI]]** application is ready. Otherwise, open it by clicking button **[[s800 daq tools#Run Control Window|Launch ULM GUI]]** in ReadoutGUI +      * Ensure that the **[[s800 daq tools#trigger GUI|trigger GUI]]** application is ready. Otherwise, open it by clicking button ''Launch ULM GUI'' in [[#ReadoutGUI|ReadoutGUI]] 
           * Under trigger tab select **s800 trigger** (which is E1 up by definition)           * Under trigger tab select **s800 trigger** (which is E1 up by definition)
           * Deselect experiment trigger           * Deselect experiment trigger
Line 74: Line 74:
           * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition           * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition
  
-  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/user/s800/operations/spectcl/s800v7/Windows**+  * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/user/s800/operations/spectcl/s800v7/Windows**. (NOTE: Spectra definition files can be found in directory **/user/s800/operations/spectcl/s800v7/Definitions**. A good file with useful spectra is **s800xdt.tcl**) 
  
   * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator   * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator
Line 170: Line 171:
       * The two spectra in the fifth row corresponds to the MTDC summary spectra of OBJ-FP and XFP-FP ToFs (zoomed in). The spectra show the ToF (vertical axis) vs. hit number (horizontal axis). Note that in a unreacted-beam setting, the first hit typically provides the "good" ToF (i.e. start and stop signals come from the same event). This is not the case in a reaction setting, where the rates in the XFP and OBJ detectors are much higher than in the FP SCI        * The two spectra in the fifth row corresponds to the MTDC summary spectra of OBJ-FP and XFP-FP ToFs (zoomed in). The spectra show the ToF (vertical axis) vs. hit number (horizontal axis). Note that in a unreacted-beam setting, the first hit typically provides the "good" ToF (i.e. start and stop signals come from the same event). This is not the case in a reaction setting, where the rates in the XFP and OBJ detectors are much higher than in the FP SCI 
       * An empty ToF spectrum means that either the delays are not right (and need to be adjusted) or the spectrum range is too narrow        * An empty ToF spectrum means that either the delays are not right (and need to be adjusted) or the spectrum range is too narrow 
-      * The MTDC spectra should never be empty because the matching window is sufficiently wide (around 4000 ns)+      * The MTDC delays should never need to be adjusted because the matching window is sufficiently wide (around 4000 ns)
  
 {{:wiki:SpecTcl-e14019-run103.jpg?850|S800_ToF.win page}} {{:wiki:SpecTcl-e14019-run103.jpg?850|S800_ToF.win page}}
Line 178: Line 179:
       * Using the cursor mouse, check the lower and higher limits defining the region in the MTDC ToF spectra with the "good" ToF peak. Do it for the three ToFs: RF-FP, OBJ-FP, and XFP-FP       * Using the cursor mouse, check the lower and higher limits defining the region in the MTDC ToF spectra with the "good" ToF peak. Do it for the three ToFs: RF-FP, OBJ-FP, and XFP-FP
       * Go to the **Variables** page in SpecTcl GUI and assign the limits to the following variables:        * Go to the **Variables** page in SpecTcl GUI and assign the limits to the following variables: 
-              * **s800.fp.vmetdc.mtdc_objlow** and **s800.fp.vmetdc.mtdc_rfhigh** for RF-XFP +              * **s800.fp.vmetdc.mtdc_rflow** and **s800.fp.vmetdc.mtdc_rfhigh** for RF-XFP 
-              * **s800.fp.vmetdc.mtdc_objlow** and **s800.fp.vmetdc.mtdc_rfhigh** for OBJ-XFP+              * **s800.fp.vmetdc.mtdc_objlow** and **s800.fp.vmetdc.mtdc_objhigh** for OBJ-XFP
               * **s800.fp.vmetdc.mtdc_xfplow** and **s800.fp.vmetdc.mtdc_xfphigh** for XFP-XFP               * **s800.fp.vmetdc.mtdc_xfplow** and **s800.fp.vmetdc.mtdc_xfphigh** for XFP-XFP
       * For each ToF, SpecTcl will search the hit number that fits in the selected region. The new MTDC ToF parameters are **s800.fp.vmetdc.mtdc_rf**, **s800.fp.vmetdc.mtdc_obj**, and **s800.fp.vmetdc.mtdc_xfp**        * For each ToF, SpecTcl will search the hit number that fits in the selected region. The new MTDC ToF parameters are **s800.fp.vmetdc.mtdc_rf**, **s800.fp.vmetdc.mtdc_obj**, and **s800.fp.vmetdc.mtdc_xfp** 
Line 282: Line 283:
  
   * Set trigger to “s800 trigger”   * Set trigger to “s800 trigger”
-      * Ensure that the **[[s800 daq tools#trigger GUI|trigger GUI]]** application is ready. Otherwise, open it by clicking icon **[[s800 daq tools#Run Control Window|RunControl]]** in the desktop of [[Software#u6pc5 (data U6)|u6pc5]] computer+      * Ensure that the **[[s800 daq tools#trigger GUI|trigger GUI]]** application is ready. Otherwise, open it by clicking ''Launch ULM GUI'' on [[#Readout GUI|Readout GUI]] in the desktop of [[Software#u6pc5 (data U6)|u6pc5]] computer
       * Under trigger tab select **s800 trigger** (which is E1 up by definition)       * Under trigger tab select **s800 trigger** (which is E1 up by definition)
           * Deselect experiment trigger           * Deselect experiment trigger
Line 336: Line 337:
               * What experimenters want (e.g., if they want singles, the cut has to be more restrictive to limit acquisition deadtime)               * What experimenters want (e.g., if they want singles, the cut has to be more restrictive to limit acquisition deadtime)
           * Move blocker, decrease attenuator, repeat           * Move blocker, decrease attenuator, repeat
 +
 +      * If necessary, do the ToF corrections to improve the PID resolution (instructions [[During experiments#Particle identification corrections|here]])
  
  
tuning_the_s800_xdt.txt · Last modified: 2023/09/22 15:15 by swartzj