This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
tuning_the_s800_xdt [2015/10/29 13:41] pereira [Setting up Reaction Settings] |
tuning_the_s800_xdt [2016/03/13 16:18] pereira [FP scintillator setup] |
||
---|---|---|---|
Line 74: | Line 74: | ||
* End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition | * End and Begin **[[s800 daq tools#Run Control Window|ReadoutGUI]]** to assert new trigger condition | ||
- | * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/ | + | * Select **[[s800 SpecTcl|Spectcl]]** window **S800_SCINT.win** in directory **/ |
* Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator | * Adjust **[[hv bias|bias]]** looking at 2D spectra **e1.deup_e1.dedown** (showing the parameters s800.fp.e1.de_down vs. s800.fp.e1.de_up) for the FP E1 scintillator | ||
Line 336: | Line 337: | ||
* What experimenters want (e.g., if they want singles, the cut has to be more restrictive to limit acquisition deadtime) | * What experimenters want (e.g., if they want singles, the cut has to be more restrictive to limit acquisition deadtime) | ||
* Move blocker, decrease attenuator, repeat | * Move blocker, decrease attenuator, repeat | ||
+ | |||
* If necessary, do the ToF corrections to improve the PID resolution (instructions [[During experiments# | * If necessary, do the ToF corrections to improve the PID resolution (instructions [[During experiments# | ||