tuning_the_s800_xdt [2023/07/24 17:51]
swartzj
tuning_the_s800_xdt [2023/08/18 17:49]
pereira [Object scintillator setup]
Line 15: Line 15:
   * Ensure that the S800 spectrograph magnets are tuned to the right rigidity   * Ensure that the S800 spectrograph magnets are tuned to the right rigidity
  
-  * Verify that the beam blocker (labeled I255 Slits) in the S3 page of Barney is open: +  * Verify that the FP beam blocker is fully open:
-      * Expected "open" values for top and bottom slits are CT ~6.8 and CB ~3.2, respectively  +
- +
-  * Ensure that CRAD04 is enabled with a rate limit of **20 kHz** (CRAD04 looks at E1 up FP scintillator)+
  
   * Remember: S800 FP rate limit is **6 kHz**   * Remember: S800 FP rate limit is **6 kHz**
Line 31: Line 28:
           * For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V)           * For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V)
  
-  * Have a good expectation of rate from A1900 group information or from timing scintillators (typically XF_SCI: extended focal-plane detector)+  * Have a good expectation of rate from ARIS group information or from timing scintillators (typically DB5)
  
-  * Remove stops to look for beam at S800 FP with **[[s800 daq tools#scaler display|scalers]]** and adjust beam rate with attenuators+  * Remove stops to look for beam at S800 FP with **[[s800 daq tools#scaler display|scalers]]** 
       * Look at FP scintillator scalers (E1 up, E1 down)       * Look at FP scintillator scalers (E1 up, E1 down)
       * There are typically a few scaler counts without beam       * There are typically a few scaler counts without beam
 +      * If needed, adjust beam rate with operators
 +
  
  
Line 44: Line 43:
   * Bias detector. Typical bias: **1200-1800 V** (up to 2200 V)   * Bias detector. Typical bias: **1200-1800 V** (up to 2200 V)
  
-  * Use **[[electronics overview|scope]]** to look at signal patched out to data U6 (channel #54 in data U6 patch panel) +  * Use oscilloscope to look at analog signal patched out to data U4 
-      * This signal is sent to the CANBERRA 454 Quad CFD in data U6 +
-      * One of the output from this CFD is sent (via patch panel #62) to the TAC and scaler (channel OBJ.Scint) in S3. The other output goes through a passive delayed, and is sent (via patch panel #67) to the Phillips TDC+
       * Check raising time and amplitude. Good signal: ~10 ns raising time; 400-500 mV amplitude       * Check raising time and amplitude. Good signal: ~10 ns raising time; 400-500 mV amplitude
 +      * Check if there are reflections (typically seen at ~300 ns after main peak)
    
   * Using the scope, check the CFD setting:   * Using the scope, check the CFD setting:
tuning_the_s800_xdt.txt · Last modified: 2023/09/22 15:15 by swartzj