Line 47: Line 47:
       * Check if there are reflections (typically seen at ~300 ns after main peak)       * Check if there are reflections (typically seen at ~300 ns after main peak)
    
 +  * Adjust MCFD threshold:
 +      * Check [[s800 daq tools#Mesytec CFD gui|Mesytec CFD GUI]] and make sure that configuration file **MCFD16.tcl**  (in directory **/user/s800/s800daq/Configurations**) is used
 +      * Trigger oscilloscope with MCFD output (see labels in patch panel), and plug analog signal
 +      * Verify that MCFD delay is ok 
 +      * Adjust MCFD gain based on signal amplitude
 +      * Adjust threshold to minimize noise
 +      * Check if MCFD output displays signals triggered by reflections (~300 ns following main peak). If that is the case, increase thresholds or signal width (this is valid only for low-rate experiments)
 +
 +      * The OBJ signal from MCFD module goes to the Mesytec MTDC module and scaler (channel OBJ.MCFD.Scint) 
 +      * Make sure that the threshold of the XFP MCFD channel is reasonable. Rates in scaler channels XFP.Scint and XFP.MCFD.Scint should be comparable
 +      * Adjust MCFD OBJ threshold looking at scalers. The ratio of OBJ to XFP scaler rates (channels OBJ.MCFD.Scint and XFP.MCFD.Scint) should reflect the transmission of the cocktail beam        
 +      * Save new threshold in configuration file **MCFD16.tcl** 
 +   
 +
 +
   * Using the scope, check the CFD setting:   * Using the scope, check the CFD setting:
       * Check CFD walk inspect signal in scope by triggering scope with CFD output       * Check CFD walk inspect signal in scope by triggering scope with CFD output
Line 56: Line 71:
           * The ratio of OBJ to XFP scaler rates (channels OBJ.Scint and XFP.Scint) should reflect the transmission of the cocktail beam (between 60% to 90%, depending on quality of tunning)           * The ratio of OBJ to XFP scaler rates (channels OBJ.Scint and XFP.Scint) should reflect the transmission of the cocktail beam (between 60% to 90%, depending on quality of tunning)
  
-  * Adjust MCFD threshold: 
-      * Using the [[s800 daq tools#Mesytec CFD gui|Mesytec CFD GUI]], open the configuration file **MCFD16.tcl**  in directory **/user/s800/s800daq/Configurations** 
-      * The OBJ signal feeding this module is not patched out to data U6 
-      * The OBJ signal from MCFD module goes to the Mesytec MTDC module and scaler (channel OBJ.MCFD.Scint)  
-      * Make sure that the threshold of the XFP MCFD channel is reasonable. Rates in scaler channels XFP.Scint and XFP.MCFD.Scint should be comparable 
-      * Adjust MCFD OBJ threshold looking at scalers. The ratio of OBJ to XFP scaler rates (channels OBJ.MCFD.Scint and XFP.MCFD.Scint) should reflect the transmission of the cocktail beam         
-      * Save new threshold in configuration file **MCFD16.tcl**  
-    
  
   * Watch for no rate change on scaler display with a bias adjustment up or down of about 50-100 V   * Watch for no rate change on scaler display with a bias adjustment up or down of about 50-100 V