turning_magnets_on_off [2014/12/05 19:59] pereira [Turn on S800 magnets power supply] |
turning_magnets_on_off [2015/10/19 14:46] pereira [Set S800 magnets settings] |
||
---|---|---|---|
Line 35: | Line 35: | ||
* Go to page 7 and select the steering magnets: **I170DH, I197DH, I231DH**. Note that some of the power supplies are connected to more than one steering magnet. If necessary, disable the steering magnet of the other line and enable the correct one. | * Go to page 7 and select the steering magnets: **I170DH, I197DH, I231DH**. Note that some of the power supplies are connected to more than one steering magnet. If necessary, disable the steering magnet of the other line and enable the correct one. | ||
- | {{: | + | {{: |
- | * **Troubleshooting**: | + | * The magnet currents corresponding to a given setting are typically set using [[Turning magnets |
- | | + | |
+ | | ||
{{: | {{: | ||
===== Set S800 magnets settings ===== | ===== Set S800 magnets settings ===== | ||
- | |||
- | * (**NOTE:** The values of currents for the different magnets can be modified individually by clicking the button " | ||
* Open **Barney** | * Open **Barney** | ||
Line 61: | Line 60: | ||
* Ensure that the current in the dipoles are properly matched to the desired values (see section on [[NMR probes# | * Ensure that the current in the dipoles are properly matched to the desired values (see section on [[NMR probes# | ||
- | | + | |
+ | |||
+ | ===== Set magnet currents individually ===== | ||
+ | The values of currents for the different magnets can be modified individually by clicking the button " | ||
+ | | ||
+ | {{: | ||
Line 69: | Line 73: | ||
* Check the currents in the Spectrograph dipoles by looking at the EPICS channels I265DS and I269DS. This can be done e.g. by clicking the button **Details** in segment 8 of the S800 Barney page (see figure below) | * Check the currents in the Spectrograph dipoles by looking at the EPICS channels I265DS and I269DS. This can be done e.g. by clicking the button **Details** in segment 8 of the S800 Barney page (see figure below) | ||
- | * The values of the current in each of the two trim coils correspond to about 53% of the currents in the corresponding Spectrograph dipoles | + | * The values of the current in each of the two trim coils correspond to about 43.5% of the currents in the corresponding Spectrograph dipoles |
* Open the NCS application **QTChan** | * Open the NCS application **QTChan** |