 ===== Venting the Chamber ===== ===== Venting the Chamber =====
  
 +From the S800 Main Vacuum page, go to the Intermediate Image - RBT_BTS32 D2430 Pumping Station page, and ensure
 +  * that the PPACs have been unbiased,
 +  * that this pumping station has been isolated by having the gate valves **D2426 BGV** and **D2436 BGV** closed, and that the IG has been turned off, and
 +  * that the turbo pump gate valve TVG is closed.
 +
 +To vent the chamber:
 +  - Monitor **RBT_BTS32:BPG_D2430:VP_RD** and **S800_GHS:PI_D2431:V_RD_AB** in a data browser,
 +  - close **RV**, the valve to the roughing pump, and
 +  - open **Vent**.
 +
 +The PPAC pressure S800_GHS:PI_D2431:V_RD_AB should closely follow the chamber pressure  
 +RBT_BTS32:BPG_D2430:VP_RD
 ===== Evacuating the Chamber ===== ===== Evacuating the Chamber =====
 +
 +{{:wiki:iimanualvalve.jpeg|}}
 ===== Filling and Running Detectors ===== ===== Filling and Running Detectors =====
   - If in Vent Mode, click **PUMP** then click **RUN** to enter Run Mode.   - If in Vent Mode, click **PUMP** then click **RUN** to enter Run Mode.