venting_pumping_object_box [2023/06/02 17:14] swartzj |
venting_pumping_object_box [2023/11/17 11:23] swartzj |
||
---|---|---|---|
Line 18: | Line 18: | ||
From S800 Vacuum Main Page, go to Object chamber page. This will open the page in the figure below. | From S800 Vacuum Main Page, go to Object chamber page. This will open the page in the figure below. | ||
* Make sure that the IG is off. | * Make sure that the IG is off. | ||
- | * When you start, you should have RV closed, FV open and the TGV valve, Vent valve, as well as the gate valves named D2341 BGV and D2303 BGV all closed. | + | * When you start, you should have RV closed, FV closed |
- | * Close FV and open RV to start pumping down the object chamber with the roughing pump. You can make a plot of the pressure vs time at BPG at this point. | + | * Open RV to start pumping down the object chamber with the roughing pump. You can make a plot of the pressure vs time at BPG at this point. |
* Section D2337 will initially be red with vacuum status: 'Bad vacuum' | * Section D2337 will initially be red with vacuum status: 'Bad vacuum' | ||
* Wait until the vacuum reading at FPG to drops to below 200 mTorr before you can safely turn on the turbo pump. | * Wait until the vacuum reading at FPG to drops to below 200 mTorr before you can safely turn on the turbo pump. |