User Tools

Site Tools


electronics_overview

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
electronics_overview [2013/12/20 15:05]
pereira [data-U6 (south end)]
electronics_overview [2014/11/19 11:48] (current)
pereira [data-U6 (south end)]
Line 15: Line 15:
   * **NIM bin**    * **NIM bin** 
         * Location: below NMR scopes in right electronics racks         * Location: below NMR scopes in right electronics racks
-        * Use: Canberra HV supply for [[Detectors#Plastic scintillators|Object scintillator]] (see rightmost module in figure below) +        * Use: Canberra HV supply for [[Detectors#Plastic scintillators|Object scintillator]] (see rightmost module in figure below) and Tennelec HV supply for the electrostatic gate of the CRDCs
  
 {{:wiki:nim-crate2-du6.jpg?400|NIM crate 2 in data-U6}} {{:wiki:nim-crate2-du6.jpg?400|NIM crate 2 in data-U6}}
  
  
-  * **Upper patch panels (top of right rack)** +  * **Top patch panels (top of right rack)** 
         * Cables 1-20: to data-U1 (signals from [[http://www.nscl.msu.edu/exp/devices#a1900|A1900]] detectors)          * Cables 1-20: to data-U1 (signals from [[http://www.nscl.msu.edu/exp/devices#a1900|A1900]] detectors) 
  
Line 26: Line 26:
  
  
-  * **Upper patch panels (top of left rack)** +  * **Top patch panels (top of left rack)** 
         * Cables 1-10: to the [[Stations#Object|object station]] (not connected in vault; maybe these go to an old target location in the transfer hall)         * Cables 1-10: to the [[Stations#Object|object station]] (not connected in vault; maybe these go to an old target location in the transfer hall)
         * Cables 11-20: to the [[Stations#Object|object station]]          * Cables 11-20: to the [[Stations#Object|object station]] 
         * Cables 21-25: to the [[Stations|intermediate image station]]         * Cables 21-25: to the [[Stations|intermediate image station]]
         * Cable 26: missing         * Cable 26: missing
-        * Cable 27-50: should go to [[Stations|target station]] (pivot point) (mostly not connect in vault)+        * Cable 27-50: should go to the [[Stations|target station (pivot point)]] (mostly not connect in vault)
  
 {{:wiki:patch-panel2-du6.jpg?500|Patch panel 2 in data-U6}} {{:wiki:patch-panel2-du6.jpg?500|Patch panel 2 in data-U6}}
Line 42: Line 42:
  
   * **Middle patch panel (middle of left rack)**    * **Middle patch panel (middle of left rack)** 
-        * Cables 51-70: to S800 FP +        * Cables 51-70: to the [[Stations|focal-plane station]]  
-        * SHV cables 1-2: to object +        * SHV cables 1-2: to the [[Stations|object station]]  
-        * SHV cables 6-10: should go to intermediate image box (apparently not connected in vault) +        * SHV cables 6-10: should go to the [[Stations|intermediate image station]] (apparently not connected in vault) 
-        * SHV cables 11-20: to pivot point (not connected in vault)+        * SHV cables 11-20: to the [[Stations|target station (pivot point)]] (not connected in vault)
  
 {{:wiki:patch-panel3-du6.jpg?500|Patch panel 3 in data-U6}} {{:wiki:patch-panel3-du6.jpg?500|Patch panel 3 in data-U6}}
  
  
-===== S800 FP (top level of S3 vault) ===== 
  
-  * **Electronics location:** bottom of right rack inside cabinet located on top level of S3 vault on north side of FP+ 
 +  * **Bottom patch panel (middle of left rack)**  
 +        * Cables 71-111: to the [[Stations|target station (pivot point)]]   
 + 
 +===== S800 Focal Plane (top level of S3 vault) ===== 
 + 
 +  * **Electronics location:** bottom of right rack inside cabinet located on top level of S3 vault on north side of the focal plane
  
   * **Patch panels:**   * **Patch panels:**
-        * SHV Cables 21-30: to data-U6 dangling at location of old S800 FP electronics under FP+        * SHV Cables 21-30: to data-U6 
         * Cables 51-70: to data-U6         * Cables 51-70: to data-U6
-        * Cables 91-110: to pivot point+        * Cables 91-110: to the [[Stations|target station (pivot point)]]
  
 {{:wiki:patch-panel-s3.jpg?500|Patch panel 3 in data-U6}} {{:wiki:patch-panel-s3.jpg?500|Patch panel 3 in data-U6}}
Line 66: Line 71:
  
   * **Patch panels**   * **Patch panels**
-        * Cables 75-110: to Data-U6 +        * Cables 75-110: to data-U6 
-        * Cables 70-80: to object  +        * Cables 70-80: to the [[Stations|object station]]  
-        * Cables 81-90: to intermediate image +        * Cables 81-90: to the [[Stations|intermediate image station]] 
-        * Cables 91-110: to S800 FP+        * Cables 91-110: to the [[Stations|focal plane station]] 
 + 
 + 
 +{{:wiki:patch-panel-target.jpg?500|Patch panel in pivot point (target).}} 
 + 
  
 ===== Intermediate Image (accessed via middle level of S3 vault) ===== ===== Intermediate Image (accessed via middle level of S3 vault) =====
Line 75: Line 85:
  
   * **Patch panels** (in electronics rack on top level of S3 vault)   * **Patch panels** (in electronics rack on top level of S3 vault)
-        * Cables 21-25:  to Data-U6 +        * Cables 21-25: to data-U6 
-        * Cables 81-90:  to pivot point+        * Cables 81-90: to the [[Stations|target station (pivot point)]] 
 +{{:wiki:patch-panel-image.jpg?500|Patch panel in intermediate image plane.}} 
  
 ===== Object position (access via middle level of S3 vault) ===== ===== Object position (access via middle level of S3 vault) =====
Line 82: Line 94:
  
   * **Patch panels** (mounted on object box support under object box)   * **Patch panels** (mounted on object box support under object box)
-        * Cables 11-20:  to Data-U6 +        * Cables 11-20: to data-U6 
-        * Cables 71-80:  to pivot point +        * Cables 71-80: to [[Stations|target station (pivot point)]] 
-        * SHV cables 1-2:  to Data-U6+        * SHV cables 1-2: to data-U6 
  
 +{{:wiki:patch-pannel-obj.jpg?500|Patch panel in object station.}}
  
  
electronics_overview.1387569903.txt.gz · Last modified: 2013/12/20 15:05 by pereira