gas_handling_system [2018/04/11 16:12]
pereira [Filling CRDC1 and CRDC2 with Gas]
gas_handling_system [2018/04/11 16:13]
pereira [Removing Gas from Focal Plane Detectors]
Line 157: Line 157:
   * Close **valves 8 and 24**   * Close **valves 8 and 24**
  
-  * Open **valves 6 and 22**+  * Open **valves 6, 7, 22 and 23**
  
   * Enter S3 vault and close valves downstream of regulators in [[#Preparation of gas bottles|gas bottles]]: P-10 and CF<sub>4</sub> (tetrafluoromethane). Close the main valve for the C<sub>4</sub>H<sub>10</sub> bottle.   * Enter S3 vault and close valves downstream of regulators in [[#Preparation of gas bottles|gas bottles]]: P-10 and CF<sub>4</sub> (tetrafluoromethane). Close the main valve for the C<sub>4</sub>H<sub>10</sub> bottle.
gas_handling_system.txt ยท Last modified: 2023/05/11 11:29 by pereira