gas_handling_system [2018/12/19 11:08]
pereira [Detector gas handling system]
gas_handling_system [2018/12/19 11:08]
pereira [Detector gas handling system]
Line 7: Line 7:
   * [[#Filling CRDC1 and CRDC2 with Gas]]   * [[#Filling CRDC1 and CRDC2 with Gas]]
   * [[#Removing Gas from Focal Plane Detectors]]   * [[#Removing Gas from Focal Plane Detectors]]
 +  * [[Venting/pumping Intermediate Image box#Filling Intermediate-image delay PPACs|Filling Intermediate-image delay PPACs with gas]]
   * [[#Tracking Gas bottles pressures|Tracking Gas bottles pressures from Barney]]   * [[#Tracking Gas bottles pressures|Tracking Gas bottles pressures from Barney]]
   * [[#Replacing Gas bottles]]   * [[#Replacing Gas bottles]]
-  * [[Venting/pumping Intermediate Image box#Filling Intermediate-image delay PPACs|Filling Intermediate-image delay PPACs with gas]]+
 ===== General Information for focal-plane gas handling system ===== ===== General Information for focal-plane gas handling system =====
 The gas handling systems for both Focal Plane gas-filled detectors – the [[Detectors#Ionization Chamber|Ionization Chamber]] and the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]] – are remotely controlled via a single LabView application running on the computer [[Software|S800FP-PC]] in the S3 vault. This computer can be accessed remotely from the desktop of computer [[Software#u6pc5 (data U6)|u6pc5]], by clicking in the icon **S800 Vault PC**, or by typing ''xfreerdp /u:s800 /v:35.9.56.104'' from a Linux terminal. A terminal will pop-up asking for the s800 password. Once the virtual session in S800FP-PC is open, the gas handling system can be opened by clicking in the corresponding icon on the desktop **FPGHS_TCPIP-II**. This icon opens the local directory ''C:/Users/s800/Desktop/FPGHS_TCPIP-II''. Once there, run the Labview executable **FPGHS_TCPIP-II.exe**.  The gas handling systems for both Focal Plane gas-filled detectors – the [[Detectors#Ionization Chamber|Ionization Chamber]] and the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]] – are remotely controlled via a single LabView application running on the computer [[Software|S800FP-PC]] in the S3 vault. This computer can be accessed remotely from the desktop of computer [[Software#u6pc5 (data U6)|u6pc5]], by clicking in the icon **S800 Vault PC**, or by typing ''xfreerdp /u:s800 /v:35.9.56.104'' from a Linux terminal. A terminal will pop-up asking for the s800 password. Once the virtual session in S800FP-PC is open, the gas handling system can be opened by clicking in the corresponding icon on the desktop **FPGHS_TCPIP-II**. This icon opens the local directory ''C:/Users/s800/Desktop/FPGHS_TCPIP-II''. Once there, run the Labview executable **FPGHS_TCPIP-II.exe**. 