gas_handling_system [2019/03/15 15:56]
pereira [LabView Control Program for focal plane detectors]
gas_handling_system [2019/09/24 07:43]
pereira [General Information for focal-plane gas handling system]
Line 12: Line 12:
  
 ===== General Information for focal-plane gas handling system ===== ===== General Information for focal-plane gas handling system =====
-The gas handling systems for both Focal Plane gas-filled detectors – the [[Detectors#​Ionization Chamber|Ionization Chamber]] and the [[Detectors#​Cathode Readout Drift Chambers (CRDC)|CRDCs]] – are remotely controlled via a single LabView application running on the computer [[Software|S800FP-PC]] in the S3 vault. This computer can be accessed remotely from the desktop of computer [[Software#​u6pc5 (data U6)|u6pc5]],​ by clicking in the icon **S800 Vault PC**, or by typing ''​xfreerdp /u:s800 /v:s800fp-win7.nscl.msu.edu''​ from a Linux terminal. A terminal will pop-up asking for the s800 password. Once the virtual session in S800FP-PC is open, the gas handling system can be opened by clicking in the corresponding icon on the desktop **FPGHS_TCPIP-II**. This icon opens the local directory ''​C:/​Users/​s800/​Desktop/​FPGHS_TCPIP-II''​. Once there, run the Labview executable **FPGHS_TCPIP-II.exe**. ​+The gas handling systems for both Focal Plane gas-filled detectors – the [[Detectors#​Ionization Chamber|Ionization Chamber]] and the [[Detectors#​Cathode Readout Drift Chambers (CRDC)|CRDCs]] – are remotely controlled via a single LabView application running on the computer [[Software|S800FP-PC]] in the S3 vault. This computer can be accessed remotely from the desktop of computer [[Software#​u6pc5 (data U6)|u6pc5]],​ by clicking in the icon **S800 Vault PC**, or by typing ''​xfreerdp /u:s800 /​v:​s800fp.nscl.msu.edu''​ from a Linux terminal. A terminal will pop-up asking for the s800 password. Once the virtual session in S800FP-PC is open, the gas handling system can be opened by clicking in the corresponding icon on the desktop **FPGHS_TCPIP-II**. This icon opens the local directory ''​C:/​Users/​s800/​Desktop/​FPGHS_TCPIP-II''​. Once there, run the Labview executable **FPGHS_TCPIP-II.exe**. ​
  
 The Labview software communicates with a MKS gas handling system through a Moax Nport 5110 terminal server attached to the bottom of the focal-plane chamber. This terminal server has a hostname s800ghts.nscl.msu.edu,​ which currently has an static IP address assigned to it (10.65.40.135). When running Labview, go to the Initialization tab and make sure that the terminal server address (IP) and port number (2001) is correct. The Labview software communicates with a MKS gas handling system through a Moax Nport 5110 terminal server attached to the bottom of the focal-plane chamber. This terminal server has a hostname s800ghts.nscl.msu.edu,​ which currently has an static IP address assigned to it (10.65.40.135). When running Labview, go to the Initialization tab and make sure that the terminal server address (IP) and port number (2001) is correct.
gas_handling_system.txt · Last modified: 2019/10/19 12:08 by pereira