User Tools

Site Tools


how_to_run_combined_s800_gretina

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
how_to_run_combined_s800_gretina [2016/03/17 09:21]
pereira
how_to_run_combined_s800_gretina [2016/03/17 10:07]
pereira
Line 2: Line 2:
 In order to run the combined S800 + Gretina daq, the following steps need to be taken: In order to run the combined S800 + Gretina daq, the following steps need to be taken:
  
 +First of all, make sure that the external synchronization and external clock () are enabled in the S800 ULM trigger module:
  
--  Start up the S800 data acquisition system as you normally would on spdaq19. 
--  Log in using the experimental account to ddasdaq3 or any other of the systems  
-   dual homed to the GRETINA/NSCLDAQ network. 
--  godaq starts the Readout control program. 
--  Click the Start button.  This will grab remote control over the S800 readout GUI. 
-   You should now be able to start runs as needed in the experiment's ReadoutGUI running 
-   on the dual homed system. 
  
-When everything has started correctly you should have the following ring buffers +  - [[S800 DAQ tools#Running the S800 DAQ|Run the S800 ReadoutGUI]] for the S800 data acquisition system as you normally would on spdaq19, and click the ''Start'' button.    
-in the dual homed system (e.gddasdaq3):+  - Log in using the experimental account to **ddasdaq3** or any other of the systems dual homed to the GRETINA/NSCLDAQ network. 
 +  - Use command ''godaq'' to run the Readout control program. 
 +  - Click the ''Start'' button.  This will grab remote control over the S800 Readout GUI. The S800 daq will now be in slave mode. 
 +  - You should now be able to start runs as needed in the experiment's ReadoutGUI running on the dual homed system.
  
- experimental-user-name  (e.g. e14045) this ring is where sampled coincidence data +You can check the ring buffers using the command **/usr/opt/nscldaq/xxxxx/bin/ringbuffer status**, where xxxxx is the nscldaq version (as of March 201611.0-020)If everything has started correctly you should have the following ring buffers in the dual homed system (e.g. ddasdaq3):
-   is placed.  This is done via a tapcatglom pipeline. +
-*  spdaq19.rawccusb will provide raw data from the S800 CAMAC crate. +
-*  spdaq19.rawvmusb - will provide raw data from the S800 VME crate. +
-*  spdaq19.s800filter - will provide the event built, reformated data from the +
-                       S800. During a run, data are pushed from this ring into the +
-                       GRETINA GEB.+
  
-In addition to the normal stagea are structure three directories are added that will +  * **experimental-user-name (e.g. e14045)**: This ring is where sampled coincidence data is placed.  This is done via a tapcat, glom pipeline. 
-be used to store raw S800 data:+  * **spdaq19.rawccusb**: It will provide raw data from the S800 CAMAC crate. 
 +  * **spdaq19.rawvmusb**: It will provide raw data from the S800 VME crate. 
 +  * **spdaq19.s800filter**It will provide the event built, reformated data from the S800 Filter. During a run, data are pushed from this ring into the GRETINA GEB.
  
- stagearea/rawccusb - Event files containing raw ccusb data from the s800. +In addition to the normal **stagearea** structure in the experiment accountthree directories are added that will be used to store raw S800 data:
- stagearea/rawvmusb - Event files containing raw vmusb data from the s800. +
-*  stagearea/s800filter - Event files containing event buildreformatted +
-                          s800 data.+
  
 +  * **~/stagearea/rawccusb**: Event files containing raw CCUSB data from the S800.
 +  * **~/stagearea/rawvmusb**: Event files containing raw VMUSB data from the S800.
 +  * **~/stagearea/s800filter**: Event files containing event build, reformatted S800 data from the S800 Filter.
  
  
- 
- 
- 
- 
- 
- 
-1. On spdaq48 in /user/s800/operations/daq/usb/TclXXUSB do: 
- 
-**wish ./RunControl.tcl** 
- 
-or, on devop2 (the S800 MAC machine) 
- 
-click on the operations folder on the lower icon bar and select runcontrol.command 
- 
-2. On a dataU machine logged in as the experimental account (e11007 for the June 2012 testing period) do 
- 
-**godaq** 
- 
-3. On spdaq44 do:  
- 
-**/usr/opt/daq/10.1/bin/ringbuffer status**. The output should look similar to: 
- 
-<code> 
- +----------------+------------+-------+-------------+--------+---------+---------+------+-------------+ 
- |Name            |data-size(k)|free(k)|max_consumers|producer|maxget(k)|minget(k)|client|clientdata(k)| 
- +----------------+------------+-------+-------------+--------+---------+---------+------+-------------+ 
- |0400x           |8195        |8195   |100          |-1      |0        |0        |-     |-            | 
- |s800            |8195        |8195   |100          |7485    |0        |0        |-     |-            | 
- |-               |-           |-      |-            |-       |-        |-        |9143  |0            | 
- |segatest        |8195        |8195   |100          |-1      |0        |0        |-     |-            | 
- |spdaq48.0400x   |8195        |8195   |100          |17205   |0        |0        |-     |-            | 
- |spdaq48.segatest|8195        |8195   |100          |-1      |0        |0        |-     |-            | 
- +----------------+------------+-------+-------------+--------+---------+---------+------+-------------+ 
-</code> 
- 
-Upon start of run there will be another client of the s800 ring, which is the pushToGEB process. This should die on end run. 
- 
- 
-The S800 daq will now be in slave mode, and run control is done from the NSCL daq window. 
  
  
  
how_to_run_combined_s800_gretina.txt · Last modified: 2020/04/01 20:25 by pereira