This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
hv_bias [2015/04/12 13:38] pereira [HV Remote control] |
hv_bias [2023/02/13 14:29] noji |
||
---|---|---|---|
Line 3: | Line 3: | ||
===== HV Remote control ===== | ===== HV Remote control ===== | ||
- | The high-voltage of the [[Detectors# | + | The high-voltage of the [[Detectors# |
+ | The GUI can be opened from the desktop of the u4pc1 computer. | ||
- | {{: | + | $ jessie_load |
+ | and use the script | ||
+ | |||
+ | $ / | ||
+ | |||
+ | The GUI control panel looks like this when the detectors are biased: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | The channel list is found elsewhere. | ||
+ | The actual HV modules are located on the top level of the S3 vault, under the FP chamber. | ||
+ | |||
+ | {{: | ||
Other examples of HV values used with different fragment beams are: | Other examples of HV values used with different fragment beams are: | ||
- | * CRDC1 and CRDC2: | + | * **CRDC1 and CRDC2**: |
* For He-3 @ ~130 MeV/u: CRDC1 (Anode=1120 V, Drift=1000 V); CRDC2 (Anode=1120 V; Drift=1000 V) | * For He-3 @ ~130 MeV/u: CRDC1 (Anode=1120 V, Drift=1000 V); CRDC2 (Anode=1120 V; Drift=1000 V) | ||
* For Be-12 @ ~30 MeV/u: CRDC1 (Anode=970 V, Drift=1000 V); CRDC2 (Anode=970 V; Drift=1000 V) | * For Be-12 @ ~30 MeV/u: CRDC1 (Anode=970 V, Drift=1000 V); CRDC2 (Anode=970 V; Drift=1000 V) | ||
Line 18: | Line 31: | ||
* For U-238 (88+) @ ~70 MeV/u: CRDC1 (Anode=570 V, Drift=1000 V); CRDC2 (Anode=570 V; Drift=1000 V) | * For U-238 (88+) @ ~70 MeV/u: CRDC1 (Anode=570 V, Drift=1000 V); CRDC2 (Anode=570 V; Drift=1000 V) | ||
| | ||
- | * FP scintillator (E1 up and E1 down): | + | * **FP scintillator (E1 up and E1 down)**: |
* For He-3 @ ~130 MeV/u: UP (1790 V); DOWN (1760 V) | * For He-3 @ ~130 MeV/u: UP (1790 V); DOWN (1760 V) | ||
* For Be-12 @ ~30 MeV/u: UP (1770 V); DOWN (1700 V) | * For Be-12 @ ~30 MeV/u: UP (1770 V); DOWN (1700 V) | ||
Line 24: | Line 37: | ||
* For Zn-58 @ ~44 MeV/u: UP (1400 V); DOWN (1340 V) | * For Zn-58 @ ~44 MeV/u: UP (1400 V); DOWN (1340 V) | ||
* For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V) | * For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V) | ||
- | ===== HV Manual control ==== | ||
- | Apart from the detectors listed above, the voltages of the [[Detectors# | ||
- | and the **electrostatic gate** of the [[Detectors# | ||
- | |||
- | The bias for the object scintillator is controlled via the H.V. power supply {{: | ||
- | |||
- | In order for the [[Detectors# | ||
- | |||
- | {{:wiki: | + | * **IC**: |
+ | * Typically 200 V | ||