hv_bias

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
hv_bias [2023/02/13 14:29]
noji
hv_bias [2023/10/17 09:40]
noji
Line 1: Line 1:
 ====== Detector bias control ====== ====== Detector bias control ======
- 
  
 ===== HV Remote control ===== ===== HV Remote control =====
-The high-voltage of the [[Detectors#Tracking Parallel Plate Avalanche Counters (TPPAC)|TPPACs]], [[Detectors#Ionization Chamber|Ion Chamber]], the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]], [[Detectors#Plastic scintillators|FP Scintillator]], and [[Detectors#Hodoscope|Hodoscope]] are remotely controlled via GUI control panel (see figure below). 
-The GUI can be opened from the desktop of the u4pc1 computer. Logging in as s800 user, start the singularity container for Debian 8 (Jessie) with 
  
-  $ jessie_load+The high-voltage of the plastic scintillator and the MCP at Object, the [[Detectors#Tracking Parallel Plate Avalanche Counters (TPPAC)|TPPACs]] at Intermediate Image, the [[Detectors#Cathode Readout Drift Chambers (CRDC)|CRDCs]], [[Detectors#Ionization Chamber|ion chamber]], [[Detectors#Plastic scintillators|plastic scintillator]], and [[Detectors#Hodoscope|hodoscope]] at Focal Plane are remotely controlled via CS-Studio Phoebus (see figure below). 
 + 
 +{{:wiki:phoebus_diag_hv.png|CS-Studio Phoebus DIAG HV control}} 
 + 
 +This “S800 HV Bias Power Supply” page is linked from both "S800" and “DIAG” launchers, a screenshot of the former of which is shown below.
  
-and use the script+{{:wiki:css_s800launcher_hv.png|}}
  
-  $ /usr/opt/iseg-beta/start.sh+The ramp rate can be changed in the "Details". ISEG cards that are used here have only one ramp rate per bank of channels, so changing the rate for one channels will change the rate for all the others in the same bank. When you ramp the HV, ensure that the ramp rate is set properly.
  
-The GUI control panel looks like this when the detectors are biased:+Each channel can also be accessed from by going to “FRIB EXP” -> “Power Supplies” and open the “EXP-S3” tab, which looks like the screenshot below.
  
-{{:wiki:iseg_slot0.png|}}+{{:wiki:phoebus_ps_main.png|CS-Studio Phoebus PS HV control}}
  
-The channel list is found elsewhere. 
 The actual HV modules are located on the top level of the S3 vault, under the FP chamber. The actual HV modules are located on the top level of the S3 vault, under the FP chamber.
  
hv_bias.txt · Last modified: 2023/10/17 09:40 by noji