nmr_probes [2023/02/13 11:05]
noji [NMR Control] The location of the digital oscilloscopes have been updated.
nmr_probes [2023/02/13 11:23]
noji [Description] Updated to reflect recent changes as to how to run the NMR GUI.
Line 9: Line 9:
  
 ===== Description ===== ===== Description =====
-The NMR running programs for both the S800 analysis line and spectrograph dipoles can be started from the desktop of computer [[Software#u6pc5 (data U6)|u6pc5]], by clicking in the icons **NMR Analysis** for the analysis line dipoles, and **NMR Spectrograph** for the spectrograph magnets. Alternatively, the NMR control programs can be run from a Linux session by typing ''/usr/bin/wish analysis.tcl'' in directory **/user/s800/Documents/Run/analysis**, for the analysis line, and ''/usr/bin.wish spectrograph_sjw.tcl'' in directory **/user/s800/Documents/Run/spectrograph**, for the spectrograph.+The NMR running programs for both the S800 analysis line and spectrograph dipoles can be started by logging in to exp-s3-nmr.ftc (10.40.230.111) accessible from the EXP network, namely, from a whatever computer connected to the EXP network, 
 + 
 +  $ ssh [your-user-name-on-EXP]@exp-s3-nmr -Y 
 + 
 +and typing, for the analysis line dipoles  
 + 
 +  $ /usr/bin/wish /srv/s3-nmr/analysis/analysis.tcl 
 + 
 +and for the spectrograph dipoles 
 + 
 +  $ /usr/bin/wish /srv/s3-nmr/spectrograph/spectrograph.tcl
  
 Sometimes the initialization of these applications fail. In that case check section [[nmr probes#troubleshooting|"Troubleshooting"]] below). The picture below shows the NMR panel for the S800 Analysis Line GUI as an example. The top (yellow) panel shows the data relevant to the NMR module, the middle (pink) the digitized signal from the oscilloscope and the bottom (blue) the status and measurements for the dipoles.  Sometimes the initialization of these applications fail. In that case check section [[nmr probes#troubleshooting|"Troubleshooting"]] below). The picture below shows the NMR panel for the S800 Analysis Line GUI as an example. The top (yellow) panel shows the data relevant to the NMR module, the middle (pink) the digitized signal from the oscilloscope and the bottom (blue) the status and measurements for the dipoles. 