s800_daq_tools [2020/03/05 12:25]
pereira [No data sources defined]
s800_daq_tools [2023/04/20 15:43]
swartzj
Line 47: Line 47:
  
  
-  * To load the default CFD configuration go to **Load Setting**, select file **MCFD16.tcl** in directory **/user/operations/daq/usb/Config**, and click **Load**+  * To load the default CFD configuration go to **Load Setting**, select file **MCFD16.tcl** in directory **/user/s800/s800daq/Configurations**, and click **Load**
    * Alternatively, it is possible to load the configuration directly from the module by clicking **Update from Device**.     * Alternatively, it is possible to load the configuration directly from the module by clicking **Update from Device**. 
    * By default, the CFD parameters can be adjusted individually for each of the 16 channels. It is also possible use the module in a "common" mode to set the same CFD parameters to all channels. Just check **common**    * By default, the CFD parameters can be adjusted individually for each of the 16 channels. It is also possible use the module in a "common" mode to set the same CFD parameters to all channels. Just check **common**
Line 53: Line 53:
   * Don't forget to save the new settings in file **MCF16.tcl**.    * Don't forget to save the new settings in file **MCF16.tcl**. 
      - Go to ''File''      - Go to ''File''
-     - Click ''Browse'' and select directory **/user/operations/daq/usb/Config** (default)+     - Click ''Browse'' and select directory **/user/s800/s800daq/Configurations** (default)
      - Select file **MCFD16tcl** and click ''Save''      - Select file **MCFD16tcl** and click ''Save''
      - A warning window will pop out to verify that you want to overwrite the existing file. Answer ''Yes''      - A warning window will pop out to verify that you want to overwrite the existing file. Answer ''Yes''
Line 132: Line 132:
   * [[#CCUSB and/or VMUSB claimed by existing programs]]   * [[#CCUSB and/or VMUSB claimed by existing programs]]
   * [[#Manual rebooting]]   * [[#Manual rebooting]]
 +  * [[#For hodoscope runs, cannot read signal from hodoscope]]
  
  
Line 164: Line 165:
 ==== Manual rebooting ==== ==== Manual rebooting ====
 In the rare case that the RunControl GUI gets "frozen", it is possible to reboot the whole system manually. This operation requires to turn off the VME and CAMAC crates, and the spdaq computer, all them located in the rack seating near the FP box in the S3 vault. Then, the system must be turned back on in the following order. First, CAMAC crate, second VME crate, and third spdaq. In the rare case that the RunControl GUI gets "frozen", it is possible to reboot the whole system manually. This operation requires to turn off the VME and CAMAC crates, and the spdaq computer, all them located in the rack seating near the FP box in the S3 vault. Then, the system must be turned back on in the following order. First, CAMAC crate, second VME crate, and third spdaq.
 +
 +==== For hodoscope runs, cannot read signal from hodoscope ====
 +If you see this kind error message when starting the DAQ with the hodoscope in the trigger (Ext. 1 in ULM gui), check the voltages on the crate which holds the hodoscope shaper modules. If they are not at the correct values, follow this procedure: 
 +  - Ordered List ItemTurn crate off
 +  - Unplug both shapers (for both hodoscopes). Just pull them but don’t fully remove the cards. 
 +  - With shapers unplugged, turn crate on and check voltages
 +  - With crate on, firmly push one of the shapers in. 
 +  - Push second shaper in
 +  - Verify crate voltages
 +This procedure works for the electronic configuration with CAEN shaper modules. 
 +
 +
  
  
  
  