User Tools

Site Tools


s800_version_0x0004

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
s800_version_0x0004 [2013/12/12 10:55]
pereira
s800_version_0x0004 [2013/12/12 10:58]
pereira
Line 31: Line 31:
 Data read from the Lecroy 2367 ULM module and a Phillips 7186H TDC. One trigger pattern followed by up to four times. Format: Data read from the Lecroy 2367 ULM module and a Phillips 7186H TDC. One trigger pattern followed by up to four times. Format:
  
 +<code>
  0xpppp 0xcttt 0xcttt ...  0xpppp 0xcttt 0xcttt ...
 +</code>
  
 where p is the trigger pattern, c is the channel within the TDC and t the data. where p is the trigger pattern, c is the channel within the TDC and t the data.
Line 41: Line 43:
 |Secondary source|11| |Secondary source|11|
  
-==S800_TOF_PACKET==+===== S800_TOF_PACKET =====
  
 Times read from both a Phillips 7186H TDC and an Ortec 566 TAC digitized by a Phillips 7164 ADC. Format: Times read from both a Phillips 7186H TDC and an Ortec 566 TAC digitized by a Phillips 7164 ADC. Format:
  
 +<code>
  0xcttt ...  0xcttt ...
 +</code>
  
-{| class="wikitable" +Time data TDC channel TAC channel | 
-Time data +|RF|12| | 
-TDC channel +|Object Scintillator|13|5| 
-TAC channel +|XFP Scintillator|14|4| 
-|- +|Si|15||
-|RF +
-|12 +
-| +
-|- +
-|Object Scintillator +
-|13 +
-|5 +
-|- +
-|XFP Scintillator +
-|14 +
-|4 +
-|- +
-|Si +
-|15 +
-| +
-|}+
  
-==S800_SCINT_PACKET==+== S800_SCINT_PACKET==
  
 Energies and times of the focal plane scintillator, read from a Lecroy 4300B FERA and a Phillips 7186H TDC. A non-zero energy generates an energy and time pair. Format: Energies and times of the focal plane scintillator, read from a Lecroy 4300B FERA and a Phillips 7186H TDC. A non-zero energy generates an energy and time pair. Format:
s800_version_0x0004.txt · Last modified: 2013/12/12 11:05 by pereira