User Tools

Site Tools


scaler_channel_description

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
scaler_channel_description [2013/12/12 12:21]
pereira created
scaler_channel_description [2019/04/10 16:55] (current)
pereira
Line 1: Line 1:
 ====== Scaler channel description ===== ====== Scaler channel description =====
-The list below is a direct copy of the scaler description file for the s800. This file maps channel names to channel numbers, and in addition determines the layout.+The list below is a direct copy of the scaler description file **s800scaler.def** in directory **/user/s800/operations/nscldaq/scalers**. This file maps channel names to channel numbers, and in addition determines the layout. Details about the S800 scaler GUI can be found [[s800 daq tools#scaler display|here]]
  
-^ Channel name ^ Channel number ^ Channel name ^ Channel number +^ Channel name   ^ Channel number ^ Description 
-Live.Trigger  10 Raw.Trigger    ^ 9 +^ S800.Source    ^ 0  Signal going to S800 ULM trigger module (generally from "up" FP scintillator photomultiplier, E1 up) | 
-| Live.Clock    12 Raw.Clock      ^ 11 +^ Second.Source  1  Signal going to Secondary ULM trigger module (e.g. GRETINA)   
-| S800.Source   | S800.Trigger   ^ 4 | +^ Ext1.Source    2  Signal going to External-1 trigger module                     
-Second.Source 1 | Second.Trigger ^ | +^ Ext2.Source    3  Signal going to External-2 trigger module                     | 
-| Ext1.Source   ^ Ext1.Trigger   +S800.Trigger   ^ 4  S800 triggers ("singles"                                    | 
-Ext2.Source   Ext2.Trigger   |  +Coinc.Trigger  5  Coincidence triggers                                          | 
-Coinc.Trigger                 +Ext1.Trigger   ^ 6  External-1 triggers                                           | 
-| E1.Up         ^ 16 | E1.Down        ^ 17 | +^ Ext2.Trigger   7  | External-2 triggers                                           
-E2.Up         ^ 18 | E2.Down        ^ 19 | +^ Second.Trigger ^ 8  Secondary triggers                                            | 
-| CRDC1.Anode   ^ 22 | CRDC2.Anode    ^ 23 | +^ Raw.Trigger    9  Raw triggers (including all sources)                          | 
-| TPPAC1        ^ 27 | TPPAC2         ^ 28 +^ Live.Trigger   10 | Live triggers (including all sources)                         
-| OBJ.Scint     24 | XFP.Scint      ^ 25 +^ Raw.Clock      ^ 11 Raw clock                                                     | 
-| TAR.Scint     26 | XFP.Scint      ^ 25 | +^ Live.Clock     12 Live clock                                                    | 
-| S800.Source   ^ 0 | OBJ.Si         ^ 26 +10Hz           ^ 14 | 10-Hz clock                                                   
-| S800.Source   0 | OBJ.Scint      ^ 24 | +^ 1Hz            ^ 15 1-Hz clock                                                    | 
-| S800.Source   ^ XFP.Scint      ^ 25 +E1.Up          ^ 16 | Signals from E1 up                                            | 
-Hodo.OR       30                ^  +E1.Down        ^ 17 | Signals from E1 down                                          | 
 +^ XFP.MCFD.Scint ^ 18 | Signals from XFP, going through new Mesytech CFD              | 
 +^ OBJ.MCFD.Scint ^ 19 | Signals from OBJ, going through new Mesytech CFD              
 +^ Galotte        ^ 20 Signals from Galotte detector (obsolete)                      | 
 +CRDC1.Anode    ^ 22 | Signals from CRDC1 anode                                      | 
 +CRDC2.Anode    ^ 23 | Signals from CRDC2 anode                                      
 +^ XFP.Scint      ^ 24 | Signals from XFP, NOT going through new Mesytech CFD          
 +OBJ.Scint      ^ 25 | Signals from OBJ, NOT going through new Mesytech CFD          
 +DPPAC1.Anode   ^ 27 Anode signal from delay-PPAC1 going through DPPAC Mesytch CFD 
 +Hodo.OR        28 OR signal from all 32 hodoscope crystals                      |
  
  
scaler_channel_description.1386868868.txt.gz · Last modified: 2013/12/12 12:21 by pereira