This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
to-do_list [2015/10/26 16:04] pereira [In data U6] |
to-do_list [2023/05/08 14:28] noji [In data U6] |
||
---|---|---|---|
Line 19: | Line 19: | ||
* Make sure Intermediate PPACs have gas | * Make sure Intermediate PPACs have gas | ||
- | ===== In data U6 ===== | + | ===== In data U4 ===== |
* Start [[Software# | * Start [[Software# | ||
- | * Source the environment file to run the DAQ: | + | ==== Setting up DAQ software ==== |
- | * Open a terminal in u6pc5 and type '' | + | |
- | * Type '' | + | |
- | * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing '' | + | * For each experiment, an S800 Device Physicist will, after backing up whatever |
- | * Create a experiment directory in **/ | + | |
- | * Go to the newly created experiment directory, and create subdirectories **s800built**, | + | |
- | * Create the stagearea link by typing '' | + | |
- | * Run the S800 DAQ with multilogger enabled, | + | |
+ | === Backup any updates === | ||
+ | |||
+ | * ~/ | ||
+ | * Compare files in the subdirectory Configurations (e.g. '' | ||
+ | * Manually add the modified filed and commit the changes, and '' | ||
+ | |||
+ | === Uninstall existing files === | ||
+ | |||
+ | * '' | ||
+ | * '' | ||
+ | |||
+ | === Install existing files === | ||
+ | |||
+ | * '' | ||
+ | * The script should relink **stagearea** to the right place, provided that the proper experimental number is given. After typing '' | ||
+ | |||
+ | === Set S800 DAQ mode === | ||
+ | |||
+ | * Set S800 DAQ in [[s800 daq tools# | ||
+ | |||
* Check [[s800 daq tools# | * Check [[s800 daq tools# | ||
+ | ===== Other items ===== | ||
* [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]] | * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]] | ||
Line 44: | Line 59: | ||
* [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters) | * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters) | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | ===== At the end of the experiment ===== | ||
+ | * Verify with S800 Device Physicist that S800 DAQ software is uninstalled. This can be done by typing script '' | ||
+ | |||
+ | * Unbias detectors, CRDC interface boards, CRDCs gate, etc | ||
+ | |||
+ | * [[Gas handling system|Remove gas]] from CRDCs and Ion Chamber | ||