to-do_list [2017/04/06 10:48]
pereira [In data U6]
to-do_list [2019/03/13 21:24]
pereira [In data U6]
Line 23: Line 23:
  
   * Source the environment file to run the DAQ:   * Source the environment file to run the DAQ:
-        * Open a terminal in u6pc5 and type ''ssh -Y spdaq19''+        * Open a terminal in u6pc5 and type ''ssh -Y spdaq50''
         * Type ''. /usr/opt/nscldaq/xxxx/daqsetup.bash'', where xxxx is the nscldaq version number (11.0-015 on Oct 26, 2015)         * Type ''. /usr/opt/nscldaq/xxxx/daqsetup.bash'', where xxxx is the nscldaq version number (11.0-015 on Oct 26, 2015)
  
-  * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing ''ls -l ~/stagearea'' in a u6pc5 terminal, you should see: **/user/s800/stagearea -> /mnt/daqtesting/s800/exxxxx**, where xxxxx corresponds to the experiment number. If the experiment number is not right, run script **goinstall** from any directory, and follow the intructions. After that, verify that the stagearea is correct.+  * Verify with S800 Device Physicist that S800 DAQ has been installed and it is ready for the experiment. S800 DAQ can be installed by typing command ''goinstalldaq'' and following the script instructions (please, contact the S800 Device Physicist if you are not sure of what you're doing). 
 + 
 + 
 +  * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing ''ls -l ~/stagearea'' in a u6pc5 terminal, you should see: **/user/s800/stagearea -> /mnt/events/operations/s800/exxxxx**, where xxxxx corresponds to the experiment number. If the experiment number is not right, contact S800 Device Physicist. 
 + 
 +  Set S800 DAQ in [[s800 daq tools#Running in Slave mode with multilogger |Slave mode and enable multilogger]] to record S800 data in the s800 stagearea.
    
   * Check [[s800 daq tools#scaler display|scalers]] while running S800 DAQ   * Check [[s800 daq tools#scaler display|scalers]] while running S800 DAQ
- 
  
   * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]]   * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]]
Line 40: Line 44:
    
   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)
 +
 +
 +
 +
 +===== At the end of the experiment =====
 +  * Verify with S800 Device Physicist that S800 DAQ software is uninstalled. This can be done by typing script ''gouninstalldaq'' (please, contact Device Physicist if you are not sure of what you're doing)
 +
 +  * Unbias detectors, CRDC interface boards, CRDCs gate, etc
 +
 +  * [[Gas handling system|Remove gas]] from CRDCs and Ion Chamber 
  
  
  