User Tools

Site Tools


to-do_list

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
to-do_list [2015/10/19 14:45]
pereira [In data U6]
to-do_list [2019/03/13 21:24] (current)
pereira [In data U6]
Line 21: Line 21:
 ===== In data U6 ===== ===== In data U6 =====
   * Start [[Software#​u6pc5 (data U6)|Software applications]] (in computer u6pc5)   * Start [[Software#​u6pc5 (data U6)|Software applications]] (in computer u6pc5)
-           + 
 +  * Source the environment file to run the DAQ: 
 +        * Open a terminal in u6pc5 and type ''​ssh -Y spdaq50''​ 
 +        * Type ''​. /​usr/​opt/​nscldaq/​xxxx/​daqsetup.bash'',​ where xxxx is the nscldaq version number (11.0-015 on Oct 26, 2015) 
 + 
 +  * Verify with S800 Device Physicist that S800 DAQ has been installed and it is ready for the experiment. S800 DAQ can be installed by typing command ''​goinstalldaq''​ and following the script instructions (please, contact the S800 Device Physicist if you are not sure of what you're doing). 
 + 
 + 
 +  * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing ''​ls -l ~/​stagearea''​ in a u6pc5 terminal, you should see: **/​user/​s800/​stagearea -> /​mnt/​events/​operations/​s800/​exxxxx**,​ where xxxxx corresponds to the experiment number. If the experiment number is not right, contact S800 Device Physicist. 
 + 
 +  * Set S800 DAQ in [[s800 daq tools#​Running in Slave mode with multilogger |Slave mode and enable multilogger]] to record S800 data in the s800 stagearea. 
 +  
 +  * Check [[s800 daq tools#​scaler display|scalers]] while running S800 DAQ 
   * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]]   * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]]
  
Line 31: Line 44:
    
   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)
 +
 +
 +
 +
 +===== At the end of the experiment =====
 +  * Verify with S800 Device Physicist that S800 DAQ software is uninstalled. This can be done by typing script ''​gouninstalldaq''​ (please, contact Device Physicist if you are not sure of what you're doing)
 +
 +  * Unbias detectors, CRDC interface boards, CRDCs gate, etc
 +
 +  * [[Gas handling system|Remove gas]] from CRDCs and Ion Chamber ​
  
  
  
to-do_list.1445280318.txt.gz · Last modified: 2015/10/19 14:45 by pereira