to-do_list [2016/02/29 12:43]
pereira [In data U6]
to-do_list [2019/03/13 21:24] (current)
pereira [In data U6]
Line 23: Line 23:
  
   * Source the environment file to run the DAQ:   * Source the environment file to run the DAQ:
-        * Open a terminal in u6pc5 and type ''​ssh -Y spdaq19''​+        * Open a terminal in u6pc5 and type ''​ssh -Y spdaq50''​
         * Type ''​. /​usr/​opt/​nscldaq/​xxxx/​daqsetup.bash'',​ where xxxx is the nscldaq version number (11.0-015 on Oct 26, 2015)         * Type ''​. /​usr/​opt/​nscldaq/​xxxx/​daqsetup.bash'',​ where xxxx is the nscldaq version number (11.0-015 on Oct 26, 2015)
  
-  * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing ''​ls -l ~/​stagearea''​ in a u6pc5 terminal, you should see: **/​user/​s800/​stagearea -> /​mnt/​daqtesting/​s800/​exxxxx**,​ where xxxxx corresponds to the experiment ​numberIf the experiment number is not right, follow the following steps: +  * Verify ​with S800 Device Physicist ​that S800 DAQ has been installed and it is ready for the experiment. ​S800 DAQ can be installed ​by typing ​command ​''​goinstalldaq'' ​and following ​the script instructions (pleasecontact ​the S800 Device Physicist if you are not sure of what you're doing).
-        * Create a experiment directory in **/​mnt/​daqtesting/​s800** ​by typing ''​mkdir exxxxx''​ +
-        * Go to the newly created experiment directoryand create subdirectories **s800built**,​ **rawccusb**,​ and **rawvmusb** +
-        * Remove ​the old stagearea link ''rm ~/​stagearea''​ +
-        * Create a new stagearea link by typing ''​ln -s /​mnt/​daqtesting/​s800/​exxxxx ~/​stagearea''​  +
-        * Run the S800 DAQ with multilogger enabled, and take some data on disk to ensure that the newly created stagearea is properly filled+
  
-  * Check [[s800 daq tools#​scaler display|scalers]] while running S800 DAQ 
  
 +  * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing ''​ls -l ~/​stagearea''​ in a u6pc5 terminal, you should see: **/​user/​s800/​stagearea -> /​mnt/​events/​operations/​s800/​exxxxx**,​ where xxxxx corresponds to the experiment number. If the experiment number is not right, contact S800 Device Physicist.
 +
 +  * Set S800 DAQ in [[s800 daq tools#​Running in Slave mode with multilogger |Slave mode and enable multilogger]] to record S800 data in the s800 stagearea.
 + 
 +  * Check [[s800 daq tools#​scaler display|scalers]] while running S800 DAQ
  
   * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]]   * [[Turning magnets on/off#Set magnet currents individually |Put 10 Amps in Spectrograph dipoles]]
Line 45: Line 44:
    
   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)
 +
 +
 +
 +
 +===== At the end of the experiment =====
 +  * Verify with S800 Device Physicist that S800 DAQ software is uninstalled. This can be done by typing script ''​gouninstalldaq''​ (please, contact Device Physicist if you are not sure of what you're doing)
 +
 +  * Unbias detectors, CRDC interface boards, CRDCs gate, etc
 +
 +  * [[Gas handling system|Remove gas]] from CRDCs and Ion Chamber ​
  
  
  
to-do_list.1456767780.txt.gz · Last modified: 2016/02/29 12:43 by pereira