User Tools

Site Tools


to-do_list

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
to-do_list [2017/06/16 19:08]
pereira [In data U6]
to-do_list [2019/03/13 21:24] (current)
pereira [In data U6]
Line 23: Line 23:
  
   * Source the environment file to run the DAQ:   * Source the environment file to run the DAQ:
-        * Open a terminal in u6pc5 and type ''​ssh -Y spdaq19''​+        * Open a terminal in u6pc5 and type ''​ssh -Y spdaq50''​
         * Type ''​. /​usr/​opt/​nscldaq/​xxxx/​daqsetup.bash'',​ where xxxx is the nscldaq version number (11.0-015 on Oct 26, 2015)         * Type ''​. /​usr/​opt/​nscldaq/​xxxx/​daqsetup.bash'',​ where xxxx is the nscldaq version number (11.0-015 on Oct 26, 2015)
  
-  * Verify that **stagearea** in u6pc5 is pointing to the right placeAfter typing ''​ls -l ~/stagearea'' ​in a u6pc5 terminal, you should see: **/​user/​s800/​stagearea -> /​mnt/​daqtesting/​s800/​exxxxx**,​ where xxxxx corresponds to the experiment number. If the experiment number is not right, run script ​**goinstall** from any directoryand follow ​the intructions. After that, verify that the stagearea is correct.+  * Verify ​with S800 Device Physicist ​that S800 DAQ has been installed and it is ready for the experimentS800 DAQ can be installed by typing ​command ​''​goinstalldaq'' ​and following ​the script ​instructions (pleasecontact ​the S800 Device Physicist if you are not sure of what you're doing).
  
-  ​* Set S800 DAQ in [[s800 daq tools#​Running in Slave mode with multilogger |Slave mode and enable multilogger]] ​for **s800filter**+ 
 +  * Verify that **stagearea** in u6pc5 is pointing to the right place. After typing ''​ls -l ~/​stagearea''​ in a u6pc5 terminal, you should see: **/​user/​s800/​stagearea -> /​mnt/​events/​operations/​s800/​exxxxx**,​ where xxxxx corresponds to the experiment number. If the experiment number is not right, contact S800 Device Physicist. 
 + 
 +  ​* Set S800 DAQ in [[s800 daq tools#​Running in Slave mode with multilogger |Slave mode and enable multilogger]] ​to record S800 data in the s800 stagearea.
    
   * Check [[s800 daq tools#​scaler display|scalers]] while running S800 DAQ   * Check [[s800 daq tools#​scaler display|scalers]] while running S800 DAQ
Line 41: Line 44:
    
   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)   * [[Magnetic-rigidity setting|Set spectrograph Brho]] (coordinate with experimenters)
 +
 +
 +
 +
 +===== At the end of the experiment =====
 +  * Verify with S800 Device Physicist that S800 DAQ software is uninstalled. This can be done by typing script ''​gouninstalldaq''​ (please, contact Device Physicist if you are not sure of what you're doing)
 +
 +  * Unbias detectors, CRDC interface boards, CRDCs gate, etc
 +
 +  * [[Gas handling system|Remove gas]] from CRDCs and Ion Chamber ​
  
  
  
to-do_list.1497654481.txt.gz · Last modified: 2017/06/16 19:08 by pereira