User Tools

Site Tools


tuning_the_s800_xdt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
tuning_the_s800_xdt [2019/03/13 21:22]
pereira [Checking Particle ID and rate at S800 FP]
tuning_the_s800_xdt [2023/08/18 17:35]
pereira [Send beam to FP]
Line 15: Line 15:
   * Ensure that the S800 spectrograph magnets are tuned to the right rigidity   * Ensure that the S800 spectrograph magnets are tuned to the right rigidity
  
-  * Verify that the beam blocker (labeled I255 Slits) in the S3 page of Barney is open: +  * Verify that the FP beam blocker is fully open:
-      * Expected "open" values for top and bottom slits are CT ~6.8 and CB ~3.2, respectively  +
- +
-  * Ensure that CRAD04 is enabled with a rate limit of **20 kHz** (CRAD04 looks at E1 up FP scintillator)+
  
   * Remember: S800 FP rate limit is **6 kHz**   * Remember: S800 FP rate limit is **6 kHz**
Line 31: Line 28:
           * For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V)           * For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V)
  
-  * Have a good expectation of rate from A1900 group information or from timing scintillators (typically XF_SCI: extended focal-plane detector)+  * Have a good expectation of rate from ARIS group information or from timing scintillators (typically DB5)
  
-  * Remove stops to look for beam at S800 FP with **[[s800 daq tools#scaler display|scalers]]** and adjust beam rate with attenuators+  * Remove stops to look for beam at S800 FP with **[[s800 daq tools#scaler display|scalers]]** 
       * Look at FP scintillator scalers (E1 up, E1 down)       * Look at FP scintillator scalers (E1 up, E1 down)
       * There are typically a few scaler counts without beam       * There are typically a few scaler counts without beam
 +      * If needed, adjust beam rate with operators
 +
  
  
Line 182: Line 181:
  
   * Select SpecTcl window **S800_TOF.win**    * Select SpecTcl window **S800_TOF.win** 
-      * The three columns correspond to the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right) +      * The three columns correspond to the **RF-FP** ToF (left), **OBJ-FP** (center), and **XFP-FP** (right). 
-      * The first (top) row corresponds to the Phillips TDC+      * The first (top) row corresponds to the Phillips TDC.
       * The second row corresponds to the MTDC with all the hits included. Note that in a unreacted-beam setting, the first hit typically provides the "good" ToF (i.e. start and stop signals come from the same event)        * The second row corresponds to the MTDC with all the hits included. Note that in a unreacted-beam setting, the first hit typically provides the "good" ToF (i.e. start and stop signals come from the same event) 
-      * The third row corresponds to the MTDC with only the first hit +      * The third row corresponds to the MTDC with only the first hit. 
-      * The fourth row corresponds to the ORTEC TACs. Note that there is not **RF-FP TAC** +      * The fourth row corresponds to the ORTEC TACs. Note that there is not **RF-FP TAC**. 
-      * The two spectra in the fifth row corresponds to the MTDC summary spectra of OBJ-FP and XFP-FP ToFs (zoomed in). The spectra show the ToF (vertical axis) vs. hit number (horizontal axis). Note that in unreacted-beam setting, the first hit typically provides the "good" ToF (i.e. start and stop signals come from the same event). This is not the case in a reaction setting, where the rates in the XFP and OBJ detectors are much higher than in the FP SCI +      * The two spectra in the fifth row correspond to the MTDC summary spectra of OBJ-FP and XFP-FP ToFs (zoomed in). The spectra show the ToF (vertical axis) vs. hit number (horizontal axis). Note that in an unreacted-beam setting, the first hit typically provides the "good" ToF (i.e. start and stop signals come from the same event). This is not the case in a reaction setting, where the rates in the XFP and OBJ detectors are much higher than in the FP SCI 
       * An empty ToF spectrum means that either the delays are not right (and need to be adjusted) or the spectrum range is too narrow        * An empty ToF spectrum means that either the delays are not right (and need to be adjusted) or the spectrum range is too narrow 
       * The MTDC delays should never need to be adjusted because the matching window is sufficiently wide (around 4000 ns)       * The MTDC delays should never need to be adjusted because the matching window is sufficiently wide (around 4000 ns)
tuning_the_s800_xdt.txt · Last modified: 2023/09/22 15:15 by swartzj