User Tools

Site Tools


tuning_the_s800_xdt

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision Both sides next revision
tuning_the_s800_xdt [2023/07/24 17:51]
swartzj
tuning_the_s800_xdt [2023/08/18 17:35]
pereira [Send beam to FP]
Line 15: Line 15:
   * Ensure that the S800 spectrograph magnets are tuned to the right rigidity   * Ensure that the S800 spectrograph magnets are tuned to the right rigidity
  
-  * Verify that the beam blocker (labeled I255 Slits) in the S3 page of Barney is open: +  * Verify that the FP beam blocker is fully open:
-      * Expected "open" values for top and bottom slits are CT ~6.8 and CB ~3.2, respectively  +
- +
-  * Ensure that CRAD04 is enabled with a rate limit of **20 kHz** (CRAD04 looks at E1 up FP scintillator)+
  
   * Remember: S800 FP rate limit is **6 kHz**   * Remember: S800 FP rate limit is **6 kHz**
Line 31: Line 28:
           * For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V)           * For U-238 (88+) @ ~70 MeV/u: UP (1180 V); DOWN (1280 V)
  
-  * Have a good expectation of rate from A1900 group information or from timing scintillators (typically XF_SCI: extended focal-plane detector)+  * Have a good expectation of rate from ARIS group information or from timing scintillators (typically DB5)
  
-  * Remove stops to look for beam at S800 FP with **[[s800 daq tools#scaler display|scalers]]** and adjust beam rate with attenuators+  * Remove stops to look for beam at S800 FP with **[[s800 daq tools#scaler display|scalers]]** 
       * Look at FP scintillator scalers (E1 up, E1 down)       * Look at FP scintillator scalers (E1 up, E1 down)
       * There are typically a few scaler counts without beam       * There are typically a few scaler counts without beam
 +      * If needed, adjust beam rate with operators
 +
  
  
tuning_the_s800_xdt.txt · Last modified: 2023/09/22 15:15 by swartzj