User Tools

Site Tools


turning_magnets_on_off

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
turning_magnets_on_off [2015/10/19 14:44]
pereira [Set magnet currents individually]
turning_magnets_on_off [2015/10/19 15:23]
pereira
Line 28: Line 28:
  
 ===== Turn on S800 magnets power supply ===== ===== Turn on S800 magnets power supply =====
 +  * **Troubleshooting**: if a power supply cannot be turned on from PanelMate, check that the power supply module is ON. The modules for all S800 magnets are located in the S3 vault on the middle level under the stairs to the top level (see figure below). If all the modules seem to be running properly, but the problem persists, contact the operators in Control Room, ext. 305.
 +
 +{{:wiki:power-supply-magnets.jpg?450|Power supply modules}} 
 +
  
   * Open the NCS PanelMate application and load file **THallps.ui**, in directory \\exp\files\control\ncsdata\General\Qt\Templates.   * Open the NCS PanelMate application and load file **THallps.ui**, in directory \\exp\files\control\ncsdata\General\Qt\Templates.
Line 40: Line 44:
  
  
-  * **Troubleshooting**: if a power supply cannot be turned on from PanelMate, check that the power supply module is ON. The modules for all S800 magnets are located in the S3 vault on the middle level under the stairs to the top level (see figure below).  
- 
-{{:wiki:power-supply-magnets.jpg?600|Power supply modules}}  
  
 ===== Set S800 magnets settings ===== ===== Set S800 magnets settings =====
Line 59: Line 60:
  
       * Ensure that the current in the dipoles are properly matched to the desired values (see section on [[NMR probes#Matching|NMR control]])       * Ensure that the current in the dipoles are properly matched to the desired values (see section on [[NMR probes#Matching|NMR control]])
 +
 +      * Note: The currents in the Trim coils will be set automatically in Barney, once the rigidity in Segment 8 was entered.
  
 ===== Set magnet currents individually ===== ===== Set magnet currents individually =====
Line 68: Line 71:
  
 =====  Turn on the trim coils of the Spectrograph dipoles =====   =====  Turn on the trim coils of the Spectrograph dipoles =====  
 +Note: The following procedure describes how to set the trim-coil currents manually. In principle, it is no longer necessary because Barney sets the currents automatically once the rigidity of segment 8 has been entered.
 +
  
        * Check the currents in the Spectrograph dipoles by looking at the EPICS channels I265DS and I269DS. This can be done e.g. by clicking the button **Details** in segment 8 of the S800 Barney page (see figure below)        * Check the currents in the Spectrograph dipoles by looking at the EPICS channels I265DS and I269DS. This can be done e.g. by clicking the button **Details** in segment 8 of the S800 Barney page (see figure below)
turning_magnets_on_off.txt ยท Last modified: 2019/05/15 11:58 by pereira