* Verify that the target area is vented. | * Verify that the target area is vented. | ||
- | * Using the EMIS controllers in the middle level of the S3 vault (see figure above), ensure that the ion gauge I225IG is turned off. | + | * Using the manual |
- | * Ensure that gate valves I246GV (between lower-dipole section and target area) and I215GV (between intermediate image area and the lower-dipole section) are closed. | + | |
- | * Open **S800vac** PanelMate. | + | |
* Go to page 4 (" | * Go to page 4 (" | ||
+ | * Ensure that gate valves I246GV (between lower-dipole section and target area) and I215GV (between intermediate image area and the lower-dipole section) are closed. | ||
* Window "VENT STATUS" | * Window "VENT STATUS" | ||
- | * Click on "VENT STATUS" | + | * Walk to the bottom level of the S3 vault, right downstream of the last two dipoles of the analysis line and verify that the manual vent valve is closed (see picture below). |
- | * Walk to the bottom level of the S3 vault, right downstream of the last two dipoles of the analysis line. Locate the I226PG Pirani gauge and ensure that it reads rough-vacuum pressure (few miliTorr). | + | * In PanelMate **S800vac** (page 4), click on "VENT STATUS" |
+ | * Walk (again) | ||
* Slowly open the manual valve (see picture below) and verify that the pressure read in I226PG raises slowly. | * Slowly open the manual valve (see picture below) and verify that the pressure read in I226PG raises slowly. | ||
* After the section is vented (atmospheric pressure) close the manual gate valve. | * After the section is vented (atmospheric pressure) close the manual gate valve. |