Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
daq:daq [2020/05/27 15:56]
jing [miscellaneous]
daq:daq [2023/01/09 09:19]
weisshaa [Troubleshoot]
Line 1: Line 1:
-======= This is DAQ page for the 2015 campaign ​======+======= New in 2022 ====== 
 +start run window is obsolete. Two scripts are available for changing the data directory. Daq needs to be stopped, directories need to exist:  
 +  * changeDataDir_maintainRunNum ​ <data dir> ​ : keeps the Run number the same, for when we need to move physics experiment data collection to another disk 
 +  * changeDataDir_resetRunNum <data dir> ​ : finds the lowest available Run number without any larger RunDir #s 
 + 
 + 
 + 
 +======= This is DAQ page from previous campaigns ​======
 The DAQ page from the former S800-GRETINA campaign in 2012 can be found at The DAQ page from the former S800-GRETINA campaign in 2012 can be found at
 https://​wikihost.nscl.msu.edu/​gretina/​doku.php/​daq:​daq_2012 https://​wikihost.nscl.msu.edu/​gretina/​doku.php/​daq:​daq_2012
Line 7: Line 14:
 ======= Troubleshoot ====== ======= Troubleshoot ======
   * S800-Gretina not correlated: Check CC setfile ~s800/​converged_daq/​Scripts/​CC0105Begin.tcl for extsynch and extclock   * S800-Gretina not correlated: Check CC setfile ~s800/​converged_daq/​Scripts/​CC0105Begin.tcl for extsynch and extclock
 +  * S800 is losing events. Check the network speed of spdaq32 by /​sbin/​ethtool eth0 and /​sbin/​ethtool eth1 , both should show speed as 1000Mb/s, if one shows 100Mb/s then the network is too slow and S800 cannot send data to GEB fast enough which will cause event loss happen.
 +  * Check the ringbuffer status, $DAQBIN/​ringbuffer status - -host=spdaq32 - -all , if the free colum becomes zero, DAQ related people needs to be notified for diagnostics.
  
 ======= Decomp Information ====== ======= Decomp Information ======
Line 25: Line 34:
  
 ======= Misc 2019 ====== ======= Misc 2019 ======
-  * Dual homed NSCL machines are spdaq32 and spdaq45+  * Dual homed NSCL machines are spdaq32 and spdaq07
  
 ====== miscellaneous ====== ====== miscellaneous ======
Line 42: Line 51:
   * [[Replace fuses of digitizer]]   * [[Replace fuses of digitizer]]
   * [[No valid decomposed events]]   * [[No valid decomposed events]]
 +  * Verify connecedt digitizers, at IOC interface, type **dbior**, it will print all identified digitizers within one bank
 +  * VME related scripts are located at /​global/​devel/​boot/​vmeArray
 +  * Check connected PVs, at IOC interface, type "​casr"​
 +  * [[ Move detectors to new Hole position ]]
  
 ====== Reboot a2 ====== ====== Reboot a2 ======

QR Code
QR Code daq:daq (generated for current page)