Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
daq:daq [2020/07/11 23:41]
jing [miscellaneous]
daq:daq [2020/07/15 16:11]
jing [Troubleshoot]
Line 7: Line 7:
 ======= Troubleshoot ====== ======= Troubleshoot ======
   * S800-Gretina not correlated: Check CC setfile ~s800/​converged_daq/​Scripts/​CC0105Begin.tcl for extsynch and extclock   * S800-Gretina not correlated: Check CC setfile ~s800/​converged_daq/​Scripts/​CC0105Begin.tcl for extsynch and extclock
 +  * S800 is losing events. Check the network speed of spdaq45 by /​sbin/​ethtool eth0 and /​sbin/​ethtool eth1 , both should show speed as 1000Mb/s, if one shows 100Mb/s then the network is too slow and S800 cannot send data to GEB fast enough which will cause event loss happen.
 +  * Check the ringbuffer status, $DAQBIN/​ringbuffer status - -host=spdaq45 - -all , if the free colum becomes zero, DAQ related people needs to be notified for diagnostics.
  
 ======= Decomp Information ====== ======= Decomp Information ======
Line 42: Line 44:
   * [[Replace fuses of digitizer]]   * [[Replace fuses of digitizer]]
   * [[No valid decomposed events]]   * [[No valid decomposed events]]
-  * Verify connecedt digitizers, at IOC interface, type dbior, it will print all identified digitizers within one bank+  * Verify connecedt digitizers, at IOC interface, type **dbior**, it will print all identified digitizers within one bank 
 +  * VME related scripts are located at /​global/​devel/​boot/​vmeArray
   * Check connected PVs, at IOC interface, type "​casr"​   * Check connected PVs, at IOC interface, type "​casr"​
  

QR Code
QR Code daq:daq (generated for current page)