Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Last revision Both sides next revision
daq:docss800grt [2015/10/02 14:00]
weisshaa
daq:docss800grt [2015/10/02 22:26]
weisshaa
Line 78: Line 78:
        
    ##    ##
-#  The S800 software runs in this system. ​ Specifically:​ +   #  The S800 software runs in this system. ​ Specifically:​ 
-#  - The S800 ReadoutGUI runs in this system. +   ​#  - The S800 ReadoutGUI runs in this system. 
-#  - The S800 dataflow ring buffers are in this system. +   ​#  - The S800 dataflow ring buffers are in this system. 
-#   +   ​#   
-set s800host spdaq19 +   ​set s800host spdaq19 
-set S800ToGretina::​S800Host $s800host +   ​set S800ToGretina::​S800Host $s800host 
- +   ​ 
-## +   ​## 
-#  The IMPSYNC button forces GRETINA to perform an imperative sychronization +   ​#  The IMPSYNC button forces GRETINA to perform an imperative sychronization 
-#  of the clock. ​ In the normal GRETINA + S800 runs this is done automatically +   ​#  of the clock. ​ In the normal GRETINA + S800 runs this is done automatically 
-#  when the run begins. ​ In the '​infinity clock' mode, when DDAS systems are +   ​#  when the run begins. ​ In the '​infinity clock' mode, when DDAS systems are 
-#  added, this is done manually. ​ Set the variable below to 0 to enable +   ​#  added, this is done manually. ​ Set the variable below to 0 to enable 
-#  manual imperative synchronization when the run is active. ​ Otherwise +   ​#  manual imperative synchronization when the run is active. ​ Otherwise  
-+   ​
-set disableImpSyncButton 1 +   ​set disableImpSyncButton 1 
- +   ​ 
- +   ​ 
-## +   ​## 
-#  Intializes the GRETINA extensions to the ReadoutGUI. ​ This also adds the +   ​#  Intializes the GRETINA extensions to the ReadoutGUI. ​ This also adds the 
-#  GRETINA specific bits of the user interface. +   ​#  GRETINA specific bits of the user interface. 
-+   ​
-mergedCallouts::​Initialize +   ​mergedCallouts::​Initialize 
- +   ​ 
-## +   ​## 
-#  Begin run actions: +   ​#  Begin run actions: 
-+   ​
-proc OnBegin runNumber { +   ​proc OnBegin runNumber { 
 +   ​
     ##     ##
     #  With GRETINA, all data recording is perfromed on GRETINA     #  With GRETINA, all data recording is perfromed on GRETINA
Line 123: Line 123:
         .impsync configure -state disabled         .impsync configure -state disabled
     }     }
- +    
-+   ​
-## +   ​## 
-#  End run actions (called after the s800 has been asked to stop) +   ​#  End run actions (called after the s800 has been asked to stop) 
-+   ​
-proc OnEnd runNumber {+   ​proc OnEnd runNumber {
     ##     ##
     #  Asks GRETINA to end its run.     #  Asks GRETINA to end its run.
Line 145: Line 145:
     set ::​EventLog::​needFinalization 1     set ::​EventLog::​needFinalization 1
     ::​EventLog::​_finalizeRun     ::​EventLog::​_finalizeRun
- +    
-+   ​
-#​-------------------- End ReadoutCallouts.tcl --------------------- +   ​#​-------------------- End ReadoutCallouts.tcl --------------------- 
- +   ​ 
- +   ​ 
-3.2 Using the GUI: +   ​3.2 Using the GUI: 
- +   ​ 
-Once your ReadoutCallouts.tcl is installed:​ +   ​Once your ReadoutCallouts.tcl is installed:​ 
- +   ​ 
-- Ensure the S800 Readout GUI is running in spdaq19. +   ​- Ensure the S800 Readout GUI is running in spdaq19. 
-- Start the GUI with +   ​- Start the GUI with 
- +   ​ 
-$DAQBIN/​ReadoutShell +   ​$DAQBIN/​ReadoutShell 
- +   ​ 
- +   ​ 
-- Click the '​Start'​ Button. ​ This takes control of the S800 system. +   ​- Click the '​Start'​ Button. ​ This takes control of the S800 system. 
-- Once the S800 has been put in remote control, you can start/​stop +   ​- Once the S800 has been put in remote control, you can start/​stop 
-  runs as you would normally do. +     ​runs as you would normally do. 
-   +     ​ 
-4.  The Big LED. +   ​4.  The Big LED. 
- +   ​ 
-This is an application that displays the GRETINA global alarm state as +   ​This is an application that displays the GRETINA global alarm state as 
-either a big Green (no alarm) or big Red (alarm) circle or '​led'​ +   ​either a big Green (no alarm) or big Red (alarm) circle or '​led'​ 
- +   ​ 
- +   ​ 
-To run it: +   ​To run it: 
- +   ​ 
-$GRTOP/​bin/​bigled [size-in-pixels] +   ​$GRTOP/​bin/​bigled [size-in-pixels] 
- +   ​ 
-The optional size-in-pixels parameter controls the size of the led. +   ​The optional size-in-pixels parameter controls the size of the led. 
-If omitted a '​reasonable'​ default size is used. +   ​If omitted a '​reasonable'​ default size is used. 
- +   ​ 
-5. GRETINA Emergency stop button. +   ​5. GRETINA Emergency stop button.  
- +   ​ 
-If the s800 readout or GUI fail, or for some reason the GRETINA GUI becomes +   ​If the s800 readout or GUI fail, or for some reason the GRETINA GUI becomes 
-unresponsive,​ it may be necessary to stop the GRETINA. +   ​unresponsive,​ it may be necessary to stop the GRETINA. 
- +   ​ 
-$GRTOP/​bin/​emstop +   ​$GRTOP/​bin/​emstop 
- +   ​ 
-Displays the current global GRETINA state and provides a button +   ​Displays the current global GRETINA state and provides a button 
-that allows you to request GRETINA to end its run. +   ​that allows you to request GRETINA to end its run. 
- +   ​ 
 +   ​