Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revision Both sides next revision
daq:mode2 [2012/05/18 08:30]
weisshaa created
daq:mode2 [2012/05/18 14:49]
campbell
Line 1: Line 1:
 +====== DAQ:Mode 2 data loss (Chris) ======
 +
 ====== Severity ====== ====== Severity ======
 +We cannot afford losing <​del>​any triggered</​del>​ data //**in an uncounted manner**//. For absolute x-section measurements with GRETINA efficiency is crucial.
  
 ====== Problem ====== ====== Problem ======
 +For S800-GRETINA data with GRETINA self-trigger only we find S800 events in Global.dat without corresponding GRETINA event.
  
-====== Progress ======+== Size of problem (from Scott'​s email)==
  
 +  In a low rate file, the following event counts were found:
 +  ​
 +       ​11,​886 coincident events (s800 and gretina present with correlated timestamp)
 +       ​719 ​   s800 only events
 +       ​15 ​    ​gretina only events (now fixed in S800 daq)
 +       
 +  So, ~6% of the decomposed data is missing.
 +  ​
 +  Also, missing gretina data is spread throughout the file, not concentrated at the beginning or end.
 +
 +====== Progress ======
 +  * 5/17/2012: Discussed losses with Mario. ​ Code review and version check to follow.

QR Code
QR Code daq:mode2 (generated for current page)