 __Detector warm II__ __Detector warm II__
   * What happened: Detector runs out of LN and really warms up   * What happened: Detector runs out of LN and really warms up
-  * IMPORTANT: detector T increased by few Kelvin only, see example ​plot {{:​fillsystem:​warm-up-example.pdf|}}.+  * IMPORTANT: detector T increased by few Kelvin only, see plot from **real-life example** (below).
   * Run run-gln-ui.sh   * Run run-gln-ui.sh
   * Say 'fill det#', confirm that you really want to fill it.   * Say 'fill det#', confirm that you really want to fill it.
Line 44: Line 44:
  
  
-Here an real-life example. After alarm got received you get following T-plot:+Here a **real-life example**. After alarm got received you get following T-plot:
 {{:​fillsystem:​warm-up-example.pdf|}}. Actually after alarm you get it up to  {{:​fillsystem:​warm-up-example.pdf|}}. Actually after alarm you get it up to 
 channel ~1100 and see T is going up. Therefore it is a real alarm. Next you do channel ~1100 and see T is going up. Therefore it is a real alarm. Next you do