Line 24: | Line 24: | ||
| Q7 | 7 | c7.2 | 43 | c12.7 | 46 | 2 | | | Q7 | 7 | c7.2 | 43 | c12.7 | 46 | 2 | | ||
| Q8 | 8 | c8.2 | 49 | c11.4 | 35 | 2 | | | Q8 | 8 | c8.2 | 49 | c11.4 | 35 | 2 | | ||
- | | Q9 | 9 | c9.2 | 55 | c14.3 | 58 | 3 | | + | | Q9 | 9 | c9.2 | 55 | c14.5 | 58 | 3 | |
- | | Q10 | | c0.2 | 2 | c14.5 | 60 | 4 | | + | | Q10 | 10 | c0.2 | 1 | c14.3 | 60 | 4 | |
^ Wall Box ^ description ^ valve ^ valve #relay ^ | ^ Wall Box ^ description ^ valve ^ valve #relay ^ | ||
Line 56: | Line 56: | ||
* Replacement Springs from Lee Spring Company :P# LP 020E 04 S316 the correct fit that will only allow 1-3 PSI max. | * Replacement Springs from Lee Spring Company :P# LP 020E 04 S316 the correct fit that will only allow 1-3 PSI max. | ||
* Valve for detector fill line ASCO Red-Hat II 8263G209LT | * Valve for detector fill line ASCO Red-Hat II 8263G209LT | ||
+ | * ASCO valve in main manifold box is 8222G002LT 24VDC | ||
+ | * Repair kit for manifold valve is 306399 Repair Kit, see quote {{ :fillsystem:asco_kit.xlsx |}} | ||
+ | |||
+ | ====== Maintenance ====== | ||
+ | |||
+ |