fillsystem:fillsystem [2017/09/22 10:55] weisshaa [part numbers] |
fillsystem:fillsystem [2019/05/29 08:54] weisshaa [part numbers (also liquid cooling)] |
||
---|---|---|---|
Line 44: | Line 44: | ||
* [[AlarmResponse]] | * [[AlarmResponse]] | ||
- | ====== part numbers ====== | + | ====== part numbers (also liquid cooling) ====== |
- | * LN sensor (new style): http://www.omega.com/ppt/pptsc.asp?ref=PR-10&Nav=hear01, 1/8 DIAMETER RTD PROBES, P# {{:fillsystem:pt100.jpg?linkonly|PR-10-2-100-1/8-2.5"-E}}, NOTE: 2.5" is custom made | + | * LN sensor (new style): http://www.omega.com/ppt/pptsc.asp?ref=PR-10&Nav=hear01, 1/8 DIAMETER RTD PROBES, P# {{:fillsystem:pt100.jpg?linkonly|PR-10-2-100-1/8-2.5-E}}, NOTE: 2.5" is custom made |
* Tube to Pipe fitting for PT100 (Swagelok # B-200-1-4BT; 1/8 Tube X 1/4 NPT Bored thru), NOTE: thread for needs to be modified. photo of modified fitting: {{:fillsystem:fittingpt100.jpg?linkonly|}} | * Tube to Pipe fitting for PT100 (Swagelok # B-200-1-4BT; 1/8 Tube X 1/4 NPT Bored thru), NOTE: thread for needs to be modified. photo of modified fitting: {{:fillsystem:fittingpt100.jpg?linkonly|}} | ||
* Replacement Springs from Lee Spring Company :P# LP 020E 04 S316 the correct fit that will only allow 1-3 PSI max. | * Replacement Springs from Lee Spring Company :P# LP 020E 04 S316 the correct fit that will only allow 1-3 PSI max. | ||
Line 51: | Line 51: | ||
* ASCO valve in main manifold box is 8222G002LT 24VDC | * ASCO valve in main manifold box is 8222G002LT 24VDC | ||
* Repair kit for manifold valve is 306399 Repair Kit, see quote {{ :fillsystem:asco_kit.xlsx |}} | * Repair kit for manifold valve is 306399 Repair Kit, see quote {{ :fillsystem:asco_kit.xlsx |}} | ||
+ | * Liquid Cooling: tubing is McMaster-Carr 5283K12 "High-Pressure Air Hose for Push-On Fittings" (LBNL says it's good not only for air) | ||
====== Maintenance ====== | ====== Maintenance ====== |