Line 1: | Line 1: | ||
====== Login on LN computer ====== | ====== Login on LN computer ====== | ||
- | The LN computer lives in the GRETINA net and doesn't know | + | The LN computer lives in the GRETINA net and since December 2015 it is accessible from NSCL network |
- | about the outside world. | + | |
* login on gateway machine nsclgw1.nscl.msu.edu | * login on gateway machine nsclgw1.nscl.msu.edu | ||
- | * login as gretina on a2.gam (35.8.35.163) | + | * login as ln on gretina-gln1.nscl.msu.edu (35.8.35.167) |
- | * login as ln on gln1 (10.0.4.11) | + | * Remember: "liquid nitrogen two for gretina" |
+ | * from a1/a2: ln@gln1 | ||
====== LN scripts ====== | ====== LN scripts ====== | ||
Line 26: | Line 26: | ||
*run-mail-que-flush.sh | *run-mail-que-flush.sh | ||
*run-view-master.sh: Output of the LN master process | *run-view-master.sh: Output of the LN master process | ||
+ | |||
+ | Making long term T plots: | ||
+ | |||
+ | *on gln machine go to ~/other/thistory-dev | ||
+ | *run there ./run-thistory.sh XXX with the last day as input parameter | ||
+ | *results th.pdf and d.pdf are written in ~/plots | ||
+ | *uncomment/comment different templates in script for covering different time ranges | ||
+ | |||
====== LN configuration ====== | ====== LN configuration ====== | ||
- | The LN configuration file is found as ~/gln/gln.fig. It is //self-explanatory//. If this file got updated, use run-gln-ui.sh script and the command "load" in there. Note: After a "load" in the UI all detector fill schedules are gone! You need to do a "fill x y z after h:mm". | + | The LN configuration file is found as ~/gln/gln.fig. It is //self-explanatory//. If this file got updated, use run-gln-ui.sh script and the command "load" in there. Note: After a "load" in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:mm". |
+ | |||
+ | |||
+ | |||
+ | |||
+ | ====== Navigate Detector Temperature(detailed) Logs ====== | ||
+ | * [[http://dl.dropbox.com/u/11735586/navtemplog.txt|gf3/temp instructions]] | ||
- | ====== ADC to channel mapping ====== | ||
- | Documentation for ADC mapping: {{:connections_1_.pdf|}} | ||
- | * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4) | + | * gf3 "file", y value asked should be 1-6 |
- | * ADC 11-17: Fill overflow Q1-Q7 (Overflow input at supply box) | + | * sp "file" loads new spectrum |
- | * ADC 41-44: Q1 crystal, crystal, preamp, preamp | + | * sp x, ds: display spectrum x (2, 3 are the LN PT100, 1 min per bin) |
- | * ADC 45-48: Q2 crystal, crystal, preamp, preamp | + | * dl l r, ds: x-expand [l:r] |
- | * ADC 49-52: Q3 crystal, crystal, preamp, preamp | + | * y0 num, ds: y-scale minimum |
- | * ADC 53-56: Q4 crystal, crystal, preamp, preamp | + | * ny num, ds: y-scale range |
- | * ADC 57-60: Q5 crystal, crystal, preamp, preamp | + | * ct num, ds: spectrum rebinning by num |
- | * ADC 61-64: Q6 crystal, crystal, preamp, preamp | + | |
- | * ADC 65-68: Q7 crystal, crystal, preamp, preamp | + | |
- | * | + |