Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
fillsystem:ln_computer [2012/05/18 19:59]
weisshaa [ADC to channel mapping]
fillsystem:ln_computer [2015/12/01 14:07]
weisshaa [Login on LN computer]
Line 4: Line 4:
  
   * login on gateway machine nsclgw1.nscl.msu.edu   * login on gateway machine nsclgw1.nscl.msu.edu
-  * login as gretina ​on a2.gam (35.8.35.163) +  * login as ln on gretina-gln1.nscl.msu.edu 
-  * login as ln on gln1 (10.0.4.11)+  * Remember: "​liquid nitrogen two for gretina"​
  
 ====== LN scripts ====== ====== LN scripts ======
Line 28: Line 28:
  
 ====== LN configuration ====== ====== LN configuration ======
-The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. Note: After a "​load"​ in the UI all detector fill schedules are gone! You need to do a "fill x y z after h:​mm"​. ​  +The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. Note: After a "​load"​ in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:​mm"​. ​  
  
 ====== ADC to channel mapping ====== ====== ADC to channel mapping ======
-Documentation for ADC mapping: {{:​connections_1_.pdf|}}+Documentation for ADC mapping: {{:​connections_1_.pdf|}} ​(OUTDATED, now we have silver boxes)
  
   * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4)   * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4)
   * ADC 11-17: Fill overflow Q1-Q7 (Overflow input at supply box)   * ADC 11-17: Fill overflow Q1-Q7 (Overflow input at supply box)
-^ Quad supply ^ LN ADC ^ LN ADC ^ PreAmp ​ADC ^ PreAmp ​ADC + 
-^ 1  ​| ​   +^ Quad supply ^ LN ADC ^ LN ADC ^ PreAmp ​^ PreAmp ​H
-^ 2 | 45 | 46 | 47 | 48 | + 1  |          ​| ​   ​
-| 3 |  |  |  |  | +   45   46   48   ​47  ​| 
-4 |  |  |  |  | +^  ​  ​49 ​ ​| ​ ​50 ​ ​| ​ ​51 ​ ​| ​ ​52 ​ | 
-5 |  |  |  |  | +^  ​  ​54 ​ ​| ​ ​56 ​ ​| ​ ​53 ​ ​| ​ ​55 ​ | 
-6 | 30 | 52 | 63 | 64 +^  ​  ​60 ​ ​| ​ ​58 ​ ​| ​ ​57 ​ ​| ​ ​59 ​ | 
-7 | 32 | 34 | 31 | 33 |+^  ​  30   ​62  ​ 63   ​61  ​
 +^  ​  ​34 ​ |  ​32   ​33  ​ 31  | 
 + 
 +PreAmp L/H: preamplifier T reading lower/​higher T  
 + 
 + 
 +====== Navigate Detector Temperature(detailed) Logs ====== 
 +  * [[http://​dl.dropbox.com/​u/​11735586/​navtemplog.txt|gf3/temp instructions]] 
 + 
 + 
 +  * gf3 "​file",​ y value asked should be 1-6 
 +  * sp "​file"​ loads new spectrum 
 +  * sp x, ds: display spectrum x (2, 3 are the LN PT100, 1 min per bin) 
 +  * dl l r, ds: x-expand [l:r] 
 +  * y0 num, ds: y-scale minimum 
 +  * ny num, ds: y-scale range 
 +  * ct num, ds: spectrum rebinning by num  ​

QR Code
QR Code fillsystem:ln_computer (generated for current page)