Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revision Both sides next revision
fillsystem:ln_computer [2013/05/07 11:08]
weisshaa
fillsystem:ln_computer [2015/12/01 14:07]
weisshaa [Login on LN computer]
Line 4: Line 4:
  
   * login on gateway machine nsclgw1.nscl.msu.edu   * login on gateway machine nsclgw1.nscl.msu.edu
-  ​* login as gretina on a2.gam (35.8.35.163) +  * login as ln on gretina-gln1.nscl.msu.edu 
-  ​* login as ln on gln1 (10.0.4.11) +  * Remember: "​liquid nitrogen two for gretina"​
-  * Rememeber: "​liquid nitrogen two for gretina"​+
  
 ====== LN scripts ====== ====== LN scripts ======
Line 29: Line 28:
  
 ====== LN configuration ====== ====== LN configuration ======
-The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. Note: After a "​load"​ in the UI all detector fill schedules are gone! You need to do a "fill x y z after h:​mm"​. ​  +The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. Note: After a "​load"​ in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:​mm"​. ​  
  
 ====== ADC to channel mapping ====== ====== ADC to channel mapping ======
-Documentation for ADC mapping: {{:​connections_1_.pdf|}}+Documentation for ADC mapping: {{:​connections_1_.pdf|}} ​(OUTDATED, now we have silver boxes)
  
   * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4)   * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4)