Line 1: Line 1:
 ====== Login on LN computer ====== ====== Login on LN computer ======
-The LN computer lives in the GRETINA net and doesn'​t know +The LN computer lives in the GRETINA net and since December 2015 it is accessible from NSCL network
-about the outside world.+
  
   * login on gateway machine nsclgw1.nscl.msu.edu   * login on gateway machine nsclgw1.nscl.msu.edu
-  * login as gretina ​on a2.gam (35.8.35.163+  * login as ln on gretina-gln1.nscl.msu.edu (35.8.35.167
-  * login as ln on gln1 (10.0.4.11)+  * Remember: "​liquid nitrogen two for gretina"​ 
 +  * from a1/​a2: ​ln@gln1
  
 ====== LN scripts ====== ====== LN scripts ======
Line 26: Line 26:
   *run-mail-que-flush.sh  ​   *run-mail-que-flush.sh  ​
   *run-view-master.sh:​ Output of the LN master process   *run-view-master.sh:​ Output of the LN master process
 +
 +Making long term T plots:
 +
 +  *on gln machine go to ~/​other/​thistory-dev
 +  *run there ./​run-thistory.sh XXX with the last day as input parameter
 +  *results th.pdf and d.pdf are written in ~/plots
 +  *uncomment/​comment different templates in script for covering different time ranges
 +
  
 ====== LN configuration ====== ====== LN configuration ======
-The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. Note: After a "​load"​ in the UI all detector fill schedules are gone! You need to do a "fill x y z after h:​mm"​. ​  +The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. Note: After a "​load"​ in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:​mm"​. ​   
 + 
  
-====== ADC to channel mapping ====== 
-Documentation for ADC mapping: {{:​connections_1_.pdf|}} 
  
-  * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4+====== Navigate Detector Temperature(detailedLogs ====== 
-  * ADC 11-17Fill overflow Q1-Q7 (Overflow input at supply box)+  * [[http://​dl.dropbox.com/​u/​11735586/​navtemplog.txt|gf3/​temp instructions]]
  
-^ Quad supply ^ LN ADC ^ LN ADC ^ PreAmp L ^ PreAmp H^ 
-^  1  |    |    |    |    | 
-^  2  |  45  |  46  |  48  |  47  | 
-^  3  |    |    |    |    | 
-^  4  |    |    |    |    | 
-^  5  |    |    |    |    | 
-^  6  |  30  |  62|  63  |  61  | 
-^  7  |  34  |  32  |  33  |  31  | 
  
-PreAmp L/Hpreamplifier T reading lower/​higher T +  * gf3 "​file",​ y value asked should be 1-6 
 +  * sp "​file"​ loads new spectrum 
 +  * sp x, dsdisplay spectrum x (2, 3 are the LN PT100, 1 min per bin) 
 +  * dl l r, ds: x-expand [l:r] 
 +  * y0 num, ds: y-scale minimum 
 +  * ny num, ds: y-scale range 
 +  * ct num, ds: spectrum rebinning by num  ​