Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
fillsystem:ln_computer [2015/12/01 14:08]
weisshaa [Login on LN computer]
fillsystem:ln_computer [2019/05/31 12:58] (current)
weisshaa [ADC to channel mapping]
Line 5: Line 5:
   * login as ln on gretina-gln1.nscl.msu.edu (35.8.35.167)   * login as ln on gretina-gln1.nscl.msu.edu (35.8.35.167)
   * Remember: "​liquid nitrogen two for gretina"​   * Remember: "​liquid nitrogen two for gretina"​
 +  * from a1/a2: ln@gln1
  
 ====== LN scripts ====== ====== LN scripts ======
Line 26: Line 27:
   *run-view-master.sh:​ Output of the LN master process   *run-view-master.sh:​ Output of the LN master process
  
-====== LN configuration ====== +Making long term T plots:
-The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. NoteAfter a "​load"​ in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:​mm"​. ​  +
  
-====== ADC to channel mapping ====== +  *on gln machine go to ~/​other/​thistory-dev 
-Documentation for ADC mapping: {{:​connections_1_.pdf|}} (OUTDATED, now we have silver boxes)+  *run there ./​run-thistory.sh XXX with the last day as input parameter 
 +  *results th.pdf and d.pdf are written in ~/plots 
 +  *uncomment/​comment different templates in script for covering different time ranges
  
-  * ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4) 
-  * ADC 11-17: Fill overflow Q1-Q7 (Overflow input at supply box) 
  
-^ Quad supply ^ LN ADC ^ LN ADC ^ PreAmp L ^ PreAmp H^ +====== ​LN configuration ====== 
-^  1  |    |    |    |    | +The LN configuration file is found as ~/​gln/​gln.fig. It is //​self-explanatory//​. If this file got updated, use run-gln-ui.sh script and the command "​load"​ in there. Note: After a "​load"​ in the UI all detector fill schedules are gone! You need to do a "ton x y z ..." or "fill x y z after h:​mm"​. ​   
-^  2  |  45  |  46  |  48  |  47  | +
-^  3  |  49  |  50  |  51  |  52  | +
-^  4  |  54  |  56  |  53  |  55  | +
-^  5  |  60  |  58  |  57  |  59  | +
-^  6  |  30  |  62  |  63  |  61  | +
-^  7  |  34  |  32  |  33  |  31  |+
  
-PreAmp L/H: preamplifier T reading lower/​higher T  
  
  

QR Code