Electronics, patch panels, and hardware
data-U6 (south end)
S800 Focal Plane (top level of S3 vault)
Pivot point (bottom level of S3 vault)
Intermediate Image (accessed via middle level of S3 vault)
Object position (access via middle level of S3 vault)
Electronics, patch panels, and hardware
data-U6 (south end)
Electronic location:
two racks that contain all the electronics and patch panels
Oscilloscope TEKSCOPE11
Use:
S800 detector
/timing diagnostics
Location: left rack on shelf below beamstop control at Image 3 of
A1900
NMR Oscilloscopes
Use: NMR resonances display
Location: upper two shelves on right electronics rack
NIM bin
Location: below NMR scopes in right electronics racks
Use: Canberra HV supply for
Object scintillator
(see rightmost module in figure below) and Tennelec HV supply for the electrostatic gate of the CRDCs
Top patch panels (top of right rack)
Cables 1-20: to data-U1 (signals from
A1900
detectors)
Top patch panels (top of left rack)
Cables 1-10: to the
object station
(not connected in vault; maybe these go to an old target location in the transfer hall)
Cables 11-20: to the
object station
Cables 21-25: to the
intermediate image station
Cable 26: missing
Cable 27-50: should go to the
target station (pivot point)
(mostly not connect in vault)
Middle patch panel (middle of left rack)
Cables 51-70: to the
focal-plane station
SHV cables 1-2: to the
object station
SHV cables 6-10: should go to the
intermediate image station
(apparently not connected in vault)
SHV cables 11-20: to the
target station (pivot point)
(not connected in vault)
Bottom patch panel (middle of left rack)
Cables 71-111: to the
target station (pivot point)
S800 Focal Plane (top level of S3 vault)
Electronics location:
bottom of right rack inside cabinet located on top level of S3 vault on north side of the focal plane
Patch panels:
SHV Cables 21-30: to data-U6
Cables 51-70: to data-U6
Cables 91-110: to the
target station (pivot point)
Pivot point (bottom level of S3 vault)
Electronics location:
one rack on bottom level of S3 vault on south side of final analysis line triplet near stairs to middle level
Patch panels
Cables 75-110: to data-U6
Cables 70-80: to the
object station
Cables 81-90: to the
intermediate image station
Cables 91-110: to the
focal plane station
Intermediate Image (accessed via middle level of S3 vault)
Electronics location:
one rack above intermediate image box located on west end of top level of S3 vault
Patch panels
(in electronics rack on top level of S3 vault)
Cables 21-25: to data-U6
Cables 81-90: to the
target station (pivot point)
Object position (access via middle level of S3 vault)
Electronics location:
under first triplet in analysis line
Patch panels
(mounted on object box support under object box)
Cables 11-20: to data-U6
Cables 71-80: to
target station (pivot point)
SHV cables 1-2: to data-U6