Electronics, patch panels, and hardware

data-U6 (south end)

  • Electronic location: two racks that contain all the electronics and patch panels
  • Oscilloscope TEKSCOPE11
    • Use: S800 detector/timing diagnostics
    • Location: left rack on shelf below beamstop control at Image 3 of A1900
  • NMR Oscilloscopes
    • Use: NMR resonances display
    • Location: upper two shelves on right electronics rack
  • NIM bin
    • Location: below NMR scopes in right electronics racks
    • Use: Canberra HV supply for Object scintillator (see rightmost module in figure below)

NIM crate 2 in data-U6

  • Upper patch panels (top of right rack)
    • Cables 1-20: to data-U1 (signals from A1900 detectors)

Patch panel 1 in data-U6

  • Upper patch panels (top of left rack)
    • Cables 1-10: to object (not connected in vault; maybe these go to an old target location in the transfer hall)
    • Cables 11-20: to object
    • Cables 21-25: to intermediate image box
    • Cable 26: missing
    • Cable 27-50: should go to pivot point (mostly not connect in vault)

Patch panel 2 in data-U6

  • Middle patch panel (middle of left rack)
    • Cables 51-70: to S800 FP
    • SHV cables 1-2: to object
    • SHV cables 6-10: should go to intermediate image box (apparently not connected in vault)
    • SHV cables 11-20: to pivot point (not connected in vault)

Patch panel 3 in data-U6

S800 FP (top level of S3 vault)

  • Electronics location: bottom of right rack inside cabinet located on top level of S3 vault on north side of FP
  • Patch panels:
    • SHV Cables 21-30: to data-U6 dangling at location of old S800 FP electronics under FP
    • Cables 51-70: to data-U6
    • Cables 91-110: to pivot point

Patch panel 3 in data-U6

Pivot point (bottom level of S3 vault)

  • Electronics location: one rack on bottom level of S3 vault on south side of final analysis line triplet near stairs to middle level
  • Patch panels
    • Cables 75-110: to Data-U6
    • Cables 70-80: to object
    • Cables 81-90: to intermediate image
    • Cables 91-110: to S800 FP

Intermediate Image (accessed via middle level of S3 vault)

  • Electronics location: one rack above intermediate image box located on west end of top level of S3 vault
  • Patch panels (in electronics rack on top level of S3 vault)
    • Cables 21-25: to Data-U6
    • Cables 81-90: to pivot point

Object position (access via middle level of S3 vault)

  • Electronics location: under first triplet in analysis line
  • Patch panels (mounted on object box support under object box)
    • Cables 11-20: to Data-U6
    • Cables 71-80: to pivot point
    • SHV cables 1-2: to Data-U6