Line 2: Line 2:
  
 You need to log on gln1, see [[LN computer]]. Go to directory ~/scripts and run ./​run-gln-ui.sh which gives the fill system interface. ​ You need to log on gln1, see [[LN computer]]. Go to directory ~/scripts and run ./​run-gln-ui.sh which gives the fill system interface. ​
-Type help for getting overview on commands.+Type help for getting overview on commands. ​Get familiar with the commands fill, clr, coff, con, abort, load, quit
  
 In some cases you need to edit the fill-system configuration file ~/​gln/​gln.fig for setting new temperature thresholds. In order In some cases you need to edit the fill-system configuration file ~/​gln/​gln.fig for setting new temperature thresholds. In order
-to apply new gln.fig configuration you need to say '​load'​ in run-gln-ui.sh and MUST RE-ENABLE the filling!+to apply new gln.fig configuration you need to say '​load'​ in run-gln-ui.sh and MUST RE-ENABLE the filling! ​You can't say '​load'​  
 +while the system is filling. Sometimes you also need to exit and start the UI again before it allows you to execute '​load'​. ​
  
 IN WORST CASE: You can always hand-fill a quad in any mounting position. IN WORST CASE: You can always hand-fill a quad in any mounting position.
Line 43: Line 44:
  
  
-Here an real-life example. After alarm got received  +Here an real-life example. After alarm got received ​you get following T-plot: 
-{{:​fillsystem:​warm-up-example.pdf|}}+{{:​fillsystem:​warm-up-example.pdf|}}. Actually after alarm you get it up to  
 +channel ~1100 and see T is going up. Therefore it is a real alarm. Next you do 
 +is logging on the gln system, run the UI, and say fill 6. Then clr and directly 
 +coff 6 (as a fill enables T checking by default). Later you see how T is recovering. 
 +dirk cell:517 203 9419 
 + 
 + 
 + 