This is an old revision of the document!


Login on LN computer

The LN computer lives in the GRETINA net and doesn't know about the outside world.

  • login on gateway machine nsclgw1.nscl.msu.edu
  • login as gretina on a2.gam (35.8.35.163)
  • login as ln on gln1 (10.0.4.11)

LN scripts

They are found in ~/scripts. The main LN program (gln_master) is a job run by root and not directly accessible by the user. Interactions happen via scripts. Most interesting is run-gln-ui.sh, the User Interface.

  • run-gln-ui.sh: User Interface, 'help' gives option
  • run-send-alarm.sh: Add your email here for receiving alarms
  • run-log.sh: Add your email here for receiving logs
  • run-log2.sh: Add your email here for receiving logs after each fill
  • run-log3.sh:
  • run-send-alarm-wd.sh
  • finish_fill.sh: script executed after fill attempt
  • run-gln-master.sh
  • run-mail-que-view.sh
  • run-time-sync.sh
  • run-backup.sh
  • run-tlog-and-plot.sh
  • run-dlog-and-plot.sh
  • run-mail-que-flush.sh
  • run-view-master.sh: Output of the LN master process

LN configuration

The LN configuration file is found as ~/gln/gln.fig. It is self-explanatory. If this file got updated, use run-gln-ui.sh script and the command “load” in there. Note: After a “load” in the UI all detector fill schedules are gone! You need to do a “fill x y z after h:mm”.

ADC to channel mapping

Documentation for ADC mapping: connections_1_.pdf

  • ADC 1-4: Manifold overflow 1-4 (Manifold overflow at supply box Q1-Q4)
  • ADC 11-17: Fill overflow Q1-Q7 (Overflow input at supply box)

^ Quad supply ^ LN ADC ^ LN ADC ^ PreAmp ADC ^ PreAmp ADC ^

1
2 45 46 47 48
3
4
5
6 30 52 63 64
7 32 34 31 33

QR Code
QR Code fillsystem:ln_computer (generated for current page)