This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
electrostatic_calculations [2015/12/02 12:32] perezlou |
electrostatic_calculations [2016/08/30 13:21] (current) perezlou [PCB Electrodes field calculations] |
||
---|---|---|---|
Line 1: | Line 1: | ||
====== Electrostatic Calculations ====== | ====== Electrostatic Calculations ====== | ||
- | We performed electrostatic calculation with Elmer FEM code to chech the uniformity of the drift field in the field cage and look for potential sparking points. | + | We performed electrostatic calculation with Elmer FEM code to check the uniformity of the drift field in the field cage and look for potential sparking points. |
- | {{ :: | + | {{ :: |
== Dimensions of the chamber == | == Dimensions of the chamber == | ||
- | 32 cm long | + | *32 cm long |
- | \\ 17cm diameter | + | *17cm diameter |
== Dimensions of the field cage == | == Dimensions of the field cage == | ||
- | 14 cm diameter | + | *14 cm diameter |
- | \\ 1.5 cm separation from the gas chamber | + | *1.5 cm separation from the gas chamber |
- | \\ 3 cm separation between cathote and the chamber | + | *3 cm separation between cathote and the chamber |
== Characteristics of the cage == | == Characteristics of the cage == | ||
- | Flexible Kapton field cage with copper electrodes printed on one side | + | *Flexible Kapton field cage with copper electrodes printed on one side |
- | \\ 83 equipotential strips (3 mm wide 0.5 mm gap) | + | |
- | \\ Drift field 200 V/cm | + | *Drift field 200 V/cm |
- | \\ Gating grid placed 2 cm above the MICROMEGAS detector | + | *Gating grid placed 2 cm above the MICROMEGAS detector |
+ | ==== Electrostatic Potential and Drift Lines ==== | ||
+ | {{ : | ||
+ | {{ : | ||
+ | ==== Electrostatic Field and Drift Lines ==== | ||
+ | {{ : | ||
+ | {{ : | ||
+ | ==== Gating grid ==== | ||
+ | {{gg_wiki_off.png? | ||
+ | {{gg_wiki_on.png? | ||
+ | *65 Wires 100 um diameter | ||
+ | *2mm pitch | ||
+ | *placed 1 cm from micromesh | ||
+ | *-200 V | ||
+ | === Garfield Simulations === | ||
+ | Gating grid off\\ | ||
+ | {{: | ||
+ | {{: | ||
+ | |||
+ | Gating grid on 2mm pitch 20V\\ | ||
+ | {{: | ||
+ | {{: | ||
+ | |||
+ | Gating grid on 2mm pitch 40V\\ | ||
+ | {{: | ||
+ | {{: | ||
+ | |||
+ | Gating grid on 1mm pitch 20V\\ | ||
+ | {{: | ||
+ | {{: | ||
+ | |||
+ | Gating Grid Transparency Calculation\\ | ||
+ | {{ : | ||
+ | |||
+ | ==== PCB Electrodes field calculations ==== | ||
+ | Calculation of the electrostatic field in the Anode electrodes, with and without an embedded electrode. | ||
+ | {{ : | ||
+ | Results available in {{: | ||