Line 1: Line 1:
 ====== Electrostatic Calculations ====== ====== Electrostatic Calculations ======
-We performed electrostatic calculation with Elmer FEM code to chech the uniformity of the drift field in the field cage and look for potential sparking points. +We performed electrostatic calculation with Elmer FEM code to check the uniformity of the drift field in the field cage and look for potential sparking points. 
-{{ ::geometry.png?direct&400 |}}+{{ ::geometry.png?300 |}}
 == Dimensions of the chamber == == Dimensions of the chamber ==
-32 cm long +  *32 cm long 
-\\ 17cm diameter+  *17cm diameter
 == Dimensions of the field cage == == Dimensions of the field cage ==
-14 cm diameter +  *14 cm diameter 
-\\ 1.5 cm separation from the gas chamber +  *1.5 cm separation from the gas chamber 
-\\ 3 cm separation between cathote and the chamber+  *3 cm separation between cathote and the chamber
 == Characteristics of the cage == == Characteristics of the cage ==
-Flexible Kapton field cage with copper electrodes printed on one side +  *Flexible Kapton field cage with copper electrodes printed on one side 
-\\ 83 equipotential strips (3 mm wide 0.5 mm gap) +  83 equipotential strips (3 mm wide 0.5 mm gap) 
-\\ Drift field 200 V/cm +  *Drift field 200 V/cm 
-\\ Gating grid placed 2 cm above the MICROMEGAS detector+  *Gating grid placed 2 cm above the MICROMEGAS detector 
 +==== Electrostatic Potential and Drift Lines ==== 
 +{{ :lines.png?300 | Gating grid off}} 
 +{{ :lines_on.png?300 | Gating grid on}} 
 +==== Electrostatic Field and Drift Lines ==== 
 +{{ :e_fielddec2015.png?300 |Electrostatic field magnitude}} 
 +{{ :e_field2_dec.png?300 | Electrostatic field uniformity in X direction }} 
 +==== Gating grid ==== 
 +{{gg_wiki_off.png?300 | Bias Off}} 
 +{{gg_wiki_on.png?300 |Bias On}} 
 +  *65 Wires 100 um diameter 
 +  *2mm pitch  
 +  *placed 1 cm from micromesh 
 +  *-200 V 
 +=== Garfield Simulations === 
 +Gating grid off\\ 
 +{{:gg_garfieldl_unbiased.png?300|}} 
 +{{:gg_garfield_potential_unbiased.png?300|}} 
 + 
 +Gating grid on 2mm pitch 20V\\ 
 +{{:gg_garfield_potential.png?300|}} 
 +{{:gg_garfield_drift.png?300|}} 
 + 
 +Gating grid on 2mm pitch 40V\\ 
 +{{:gg_garfield_potential_40.png?300|}} 
 +{{:gg_garfield_drift40.png?300|}} 
 + 
 +Gating grid on 1mm pitch 20V\\ 
 +{{:gg_garfield_potential_1mm.png?300|}} 
 +{{:gg_garfield_drift_1mm.png?300|}} 
 + 
 +Gating Grid Transparency Calculation\\ 
 +{{ :gg_transmission.png?300 |}} 
 + 
 +==== PCB Electrodes field calculations ==== 
 +Calculation of the electrostatic field in the Anode electrodes, with and without an embedded electrode. 
 +{{ :electrodes.png?300 |}} 
 +Results available in {{:electrodes.pdf|}}
  