Electrostatic Calculations

We performed electrostatic calculation with Elmer FEM code to chech the uniformity of the drift field in the field cage and look for potential sparking points.

Dimensions of the chamber
  • 32 cm long
  • 17cm diameter
Dimensions of the field cage
  • 14 cm diameter
  • 1.5 cm separation from the gas chamber
  • 3 cm separation between cathote and the chamber
Characteristics of the cage
  • Flexible Kapton field cage with copper electrodes printed on one side
  • 83 equipotential strips (3 mm wide 0.5 mm gap)
  • Drift field 200 V/cm
  • Gating grid placed 2 cm above the MICROMEGAS detector

Electrostatic Potential and Drift Lines

 Gatind grid off  Gatind grid on

Electrostatic Field and Drift Lines

Electrostatic field magnitude  Electrostatic field uniformity in X direction

Gating grid

 Bias Off Bias On

  • 65 Wires 100 um diameter
  • 2mm pitch
  • placed 1 cm from micromesh
  • -200 V

Garfield Simulations